Write Protections; Table 11. Access Versus Read Protection Level; Figure 5. Rdp Levels - ST STM32F410 Reference Manual

Advanced arm-based 32-bit mcus
Table of Contents

Advertisement

RM0401
--
Memory area
Main Flash Memory
Option Bytes
OTP
1. The main Flash memory is only erased when the RDP changes from level 1 to 0. The OTP area remains unchanged.
Figure 5
3.6.4

Write protections

Up to 5 user sectors in Flash memory can be protected against unwanted write operations
due to loss of program counter contexts. When the non-write protection nWRPi bit (0 ≤ i ≤ 4)
in the FLASH_OPTCR registers is low, the corresponding sector cannot be erased or
programmed. Consequently, a mass erase cannot be performed if one of the sectors is
write-protected.

Table 11. Access versus read protection level

Debug features, Boot from RAM or
Protection
from System memory bootloader
Level
Read
Level 1
Level 2
Level 1
Level 2
Level 1
Level 2
shows how to go from one RDP level to another.
Write
Erase
(1)
NO
NO
NO
YES
NO
NO
NA
NO
NA

Figure 5. RDP levels

RM0401 Rev 3
Embedded Flash memory interface
Booting from Flash memory
Read
Write
YES
YES
YES
NO
YES
YES
Erase
NA
NA
57/771