Spring Unit; Fuse Capacities; Earth Leakage Trips - Maytag MFS80 Installation Instructions Manual

Commercial washer
Table of Contents

Advertisement

Spring Unit

Models MFS80, MFS100, and MFS125:
Adjust the spring units if a suspension part is not horizontal
(without wash load and water) or after the spring unit has been
replaced.
To adjust the spring unit, turn the nuts (2) the same number
of turns simultaneously on the opposite guiding rods (3). The
adjustment is correct when the gap in all four corners of the
suspended part is the same (X = 2.16"/55 mm) between the
plate edge (4) of the suspended part and the top surface of
the frame (5).
1. Spring unit
2. Adjusting nuts
3. Guiding rods
4. Suspended part
5. Washer frame
6. Spring suspension eyes
22
4
X
5
1
2
6
Models MFS180, MFS230, and MFS275:
These models are to be adjusted by the manufacturer.
6
Check Wire
2
Diagram for
Fuse Number
Fuse 1
Fuse 2
3
Fuse 3
Fuse 4
IMPORTANT: A qualified technician must perform an earth
leakage trip function test at least once every 3 months.
If the washer is equipped with an earth leakage trip in the inlet
circuit of the electric switchboard, it must be tested regularly. The
earth leakage trip is very sensitive and helps avoid electric shock
during washer operation.
To test:
Press the earth leakage trip test button while the trip is under
tension. If the trip is functioning, it will shut off.
6
2
4
1
1. Spring unit
2. Suspended part
3. Guiding rods
4. Washer frame
6. Spring suspension eyes

Fuse Capacities

MFS55 Only
Other Models
(208-500V)
(<250 Volt)
1A/500V
2.5 Amp/250V
1A/500V
2.5 Amp/250V
1.6A/250V
1.6A/250V
1A/250V
1A/250V

Earth Leakage Trips

3
6
Other Models
(250-500 Volt)
1A/500V
1A/500V
1.6A/250V
1A/250V