NEC 78K0 Series User Manual page 547

8-bit single-chip microcontrollers
Hide thumbs Also See for 78K0 Series:
Table of Contents

Advertisement

Figure 24-7. Timing of Low-Voltage Detector Interrupt Signal Generation
(1) In 1.59 V POC mode (option byte: POCMODE = 0)
Supply voltage (V
)
DD
V
LVI
V
= 1.59 V (TYP.)
POC
LVIMK flag
(set by software)
LVISEL flag
(set by software)
L
<2>
LVION flag
(set by software)
LVIF flag
INTLVI
LVIIF flag
LVIMD flag
(set by software) L
Internal reset signal
Notes 1.
The LVIMK flag is set to "1" by reset signal generation.
2.
The interrupt request signal (INTLVI) is generated and the LVIF and LVIIF flags may be set (1).
Remark <1> to <9> in Figure 24-7 above correspond to <1> to <9> in the description of "When starting
operation" in 24.4.2 (1) When detecting level of supply voltage (V
CHAPTER 24 LOW-VOLTAGE DETECTOR
(Detects Level of Supply Voltage (V
<1>
Note 1
<8> Cleared by software
<3>
<4>
<5> Wait time
<6>
Note 2
Note 2
<7>
Cleared by software
Note 2
<9>
Preliminary User's Manual U17260EJ3V1UD
)) (1/2)
DD
).
DD
Time
547

Hide quick links: