NEC 78K0 Series User Manual page 382

8-bit single-chip microcontrollers
Hide thumbs Also See for 78K0 Series:
Table of Contents

Advertisement

Minimum permissible data frame length: FLmin = 11 × FL −
Therefore, the maximum receivable baud rate at the transmission destination is as follows.
BRmax = (FLmin/11)
Similarly, the maximum permissible data frame length can be calculated as follows.
10
× FLmax = 11 × FL −
11
21k – 2
FLmax =
20k
Therefore, the minimum receivable baud rate at the transmission destination is as follows.
BRmin = (FLmax/11)
The permissible baud rate error between UART6 and the transmission destination can be calculated from the
above minimum and maximum baud rate expressions, as follows.
Table 15-6. Maximum/Minimum Permissible Baud Rate Error
Division Ratio (k)
8
20
50
100
255
Remarks 1. The permissible error of reception depends on the number of bits in one frame, input clock
frequency, and division ratio (k). The higher the input clock frequency and the higher the division
ratio (k), the higher the permissible error.
2. k: Set value of BRGC6
382
CHAPTER 15 SERIAL INTERFACE UART6
22k
1
=
Brate
21k + 2
21k − 2
k + 2
× FL =
FL
2 × k
2 × k
FL × 11
20k
1
=
Brate
21k − 2
Maximum Permissible Baud Rate Error
+3.53%
+4.26%
+4.56%
+4.66%
+4.72%
Preliminary User's Manual U17260EJ3V1UD
k − 2
21k + 2
× FL =
FL
2k
2k
Minimum Permissible Baud Rate Error
−3.61%
−4.31%
−4.58%
−4.67%
−4.73%

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents