Pressure Build Up-Opening Pressure/Close Gun; Motor Stop - Standby Pressure - Husqvarna PW 235 Workshop Manual

Table of Contents

Advertisement

Appendices and schedules

4.2.3 Pressure build up-opening pressure/close gun

Gun close. Pressure build up. Opening pressure. Micro switch is activated
Non return valve
130 BAR
Outlet
4.2.4

Motor stop - standby pressure

Gun close. Motor stops. Pressure in hose decreases to standby pressure
Pump pressure is also standby pressure.
Non return valve
Outlet
25 BAR
14 – English
Pump
130 BAR
Inlet
Pump
25 BAR
Inlet
3 BAR
3 BAR