Troubleshooting The Control Unit Bldc - S/N Up To: Lil -2015080000, S/N Up To:lir -2015100000; Troubleshooting The Control Unit Bldc - S/N From: Lil, Lilx 2015080000-, S/N From: Lir, Lirx/Irx 201510000 - Husqvarna 536LiL Workshop Manual

Hide thumbs Also See for 536LiL:
Table of Contents

Advertisement

A
C
D
6.6 Troubleshooting the control unit BLDC -
S/N up to: LiL -2015080000, S/N up to:LiR
-2015100000
Make sure that the blade terminals and related wires are
not bent or damaged.
(A) 6.3x0.8 mm M- (Black wire)
(B) 6.3x0.8 mm M+ (Red wire)
(C) 6.3x0.8 mm PCB + (Yellow wire)
(D) 6.3x0.8 mm PCB 0V (Black wire)
(E) 4.8x0.8 mm Shutdown (Blue wire)
A
C
D
E
737 - 002 - 25.10.2018
6.7 Troubleshooting the control unit BLDC -
S/N from: LiL, LiLX 2015080000-, S/N from:
LiR, LiRX/iRX 201510000-
Make sure that the blade terminals and related wires are
not bent or damaged.
(A) 6.3x0.8 mm M- (Black wire)
(B) 6.3x0.8 mm M+ (Red wire)
B
(C) 6.3x0.8 mm PCB + (Yellow wire)
(D) 6.3x0.8 mm PCB 0V (Black wire)
E
(E) 4.8x0.8 mm Shutdown (Blue wire)
B
A
B
C
Troubleshooting - 41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

520ilx536lilx536lir536lirx520irx136lic ... Show all

Table of Contents