INSTALLATION INSTRUCTIONS
The humidistat is designed for either return air duct or wall
mounting. Packaged in a duct mount configuration, (For this type
mounting begin installation at the section labeled return air duct
installation on page 2.) for conversion to a wall mount configuration
simply pull off the knob and remove the mounting screws and rotate the
control 180° and reattach the mounting base, (For this type mounting
begin installation at the section labeled wall mount installation on
page 3.).
DANGER
Do not cut or drill any air-conditioning or electrical
∗
accessories during installation.
Fatal electrocution is possible if you contact a live wire.
∗
Electrical power can cause electrical shock
∗
Disconnect all electrical power supplied to the equipment
∗
before beginning installation.
Blindness can occur if freon contacts your eyes.
∗
CAUTION
Do not install on any electrical system over 30 VAC
∗
CAUTION
All electrical wiring should comply with codes and
∗
ordinances.
Recommended Settings
At Outside Temperatures
-20°F -30°C
-10°F -25°C
0°F -20°C
+10°F -10°C
+20°F -5°C
Over 20°F Over 0°C
SK0-0055-001 HUMIDISTAT
Recommended Setting
15%
20%
25%
30%
35%
40%
Warning:
Adjusting the
humidity control
higher than the rec-
ommended setting
may cause conden-
sation resulting in
possible damage to
home.
the
Page 1