Skuttle Indoor Air Quality Products SK0-0055-001 Installation Instructions

Skuttle indoor air quality products thermostat user manual

Advertisement

INSTALLATION INSTRUCTIONS

The humidistat is designed for either return air duct or wall
mounting. Packaged in a duct mount configuration, (For this type
mounting begin installation at the section labeled return air duct
installation on page 2.) for conversion to a wall mount configuration
simply pull off the knob and remove the mounting screws and rotate the
control 180° and reattach the mounting base, (For this type mounting
begin installation at the section labeled wall mount installation on
page 3.).
DANGER
Do not cut or drill any air-conditioning or electrical
accessories during installation.
Fatal electrocution is possible if you contact a live wire.
Electrical power can cause electrical shock
Disconnect all electrical power supplied to the equipment
before beginning installation.
Blindness can occur if freon contacts your eyes.
CAUTION
Do not install on any electrical system over 30 VAC
CAUTION
All electrical wiring should comply with codes and
ordinances.
Recommended Settings
At Outside Temperatures
-20°F -30°C
-10°F -25°C
0°F -20°C
+10°F -10°C
+20°F -5°C
Over 20°F Over 0°C
SK0-0055-001 HUMIDISTAT
Recommended Setting
15%
20%
25%
30%
35%
40%
Warning:
Adjusting the
humidity control
higher than the rec-
ommended setting
may cause conden-
sation resulting in
possible damage to
home.
the
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SK0-0055-001 and is the answer not in the manual?

Questions and answers

Summary of Contents for Skuttle Indoor Air Quality Products SK0-0055-001

  • Page 1: Installation Instructions

    Recommended Settings At Outside Temperatures -20°F -30°C -10°F -25°C 0°F -20°C +10°F -10°C +20°F -5°C Over 20°F Over 0°C SK0-0055-001 HUMIDISTAT Warning: Recommended Setting Adjusting the humidity control higher than the rec- ommended setting may cause conden- sation resulting in possible damage to home.
  • Page 2 RETURN AIR DUCT INSTALLATION 1 Locate the humidistat in the return air duct at least 12 in. up stream prior to the humidifier or the humidifier by-bass tube. 2 Remove the backing and adhere the humidistat mounting template in a horizontal position, make sure it is level. 3 Drill four 7/64 in.
  • Page 3 WALL MOUNT INSTALLATION 1 Locate the humidistat about 5 ft. above the floor, on an inside wall, away from discharge registers. Also, avoid areas with extreme variation in relative humidity levels; i.e. bathrooms and kitchens. When wall mounting, homeowners usually prefer the humidistat mounted beside, or in the vicinity of the heating thermostat.
  • Page 4 WIRING INSTRUCTIONS CAUTION: ∗ Use the wiring diagram shown for single speed blower operation only. ∗ When wiring multispeed blower systems use a A50 relay or a fan sail switch to prevent premature component failure. ∗ Consult the instructions included with the humidifier and any additional controls for instructions on wiring.