Installation notes:
a
Apply RheoGel 793 to the top and bottom of the shutter blade extension.
b
Apply RheoGel 793 to the point of contact between the bracket (A) and cam.
c
Apply RheoGel 793 to the point of contact to the lower edge (B), where the wiper bracket glides.
Sensor (paper present) removal
1
Remove the rear cover. See
2
Remove the power supply. See
3
Remove the duplex. See
B
"Rear door and cover removal" on page
"Power supply removal" on page
"Duplex assembly removal" on page
Parts removal
A
234.
216.
218.
224