How To Check Fault Symptom; No Power - Samsung UE32H6200AW Service Manual

Chassis u8dc
Table of Contents

Advertisement

4. Troubleshooting

4-2. How to Check Fault Symptom

4-2-1. NO Power

Note
Refer to the next page to check the location such a CN201 or IC201 SVC Manual mentioned.
The LEDs on The front panel do not work when connecting The power cord.
Symptom
The SMPS relay does not work when connecting The power cord.
The units appears to be dead.
The IP relay or the LEDs on the front panel does not work when connecting the power cord if the cables are
improperly connected or the Main Board or SMPS is not functioning. In this case, check the following:
Check the internal cable connection status inside the unit.
Major
Check the fuses of each part.
checkpoints
Check the output voltage of SMPS.
Replace the Main Board.
Diagnostics
4-4
Power indicator LED is on?
Yes
Check the backlight on, when 18 PIN
cable unconnected ?
Yes
Check 'Stand-By 5V' ?
L204 : A5.3V
-
Yes
Check 'Power input of Main Ass'y' ?
BD201/206/209/214 : A13V
-
Yes
Check 'Power IC output of Main Ass'y' ?
IC202 : A3.3V
-
L305/306 : B1.1V / L201 : B5V
-
L203 : B3.3V / L2001 : A1.5V
-
Yes
Check Input power of 'T CON Board' ?
F1(T CON) : B13V
-
Yes
Check Power of 'T CON Board'.
BD1(T CON) : Panel_12V
-
B1.1V(T CON-TP) : FT1_1.1V_PW
-
No
Check the power cord connection.
No
Change 18p cable.
No
Change Main Power Ass'y.
No
No
Change the Main Ass'y.
Reconnect or Change.
No
the LVDS cable.
No
Change the T CON Board.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents