6.7. Parameter settings: Diagnostics

The diagram below shows the "Parameters / Diagnostic" menu accessible from "Main menu / Parameters".
"Diagnostic / Fault History" : This menu accesses the detected fault history.
"Diagnostic / Clear Faults" : This menu is used to clear the detected fault history
Parameters
Diagnostic
Diagnostic
fault1
See the table of
faults codes
Diagnostic
below
fault2
Diagnostic
fault3
Parameter writer display
Warning:
Low Battery Level
Switch off Low battery
Store config fault
Load config fault
Wrong reference Fault
No device connected
No file selected
SD card fault
SD card
Write protected
Flash FW Fault
ENT
ESC
Diagnostic
Fault History
ENT
ESC
ESC
ESC
Probable cause
The battery charge is low. The appearance
of this message depends on the charge
level defined by the user. (See setting
the detection section 6.6)
The battery charge is too low.
The Parameter writer will turn off.
Incomplete or incorrect transfer to the
inverter.
The inverter is in parameter change
prohibition state.
Incomplete or incorrect transfer from
the Parameter writer to the inverter
The inverter is in parameter read
prohibition state.
Bad transfer to the inverter; the
configuration
file selected is not compatible with the
destination inverter.
The inverter is not connected or is
incorrectly connected.
No configuration file is selected. There is
no file present on the SD card.
The card is not recognized.
The SD card is locked.
For factory use only
ESC
Diagnostic
Clear faults
ENT
ESC
Are you sure to
clear faults?
ENT
Clear faults
History done
ENT
- Make sure you have a set of replacement
batteries to hand, as the current set have little
life left.
- Replace the batteries immediately. No more
transfers can be made.
- Check the RJ45 cable and both of its
connectors. Make sure the connection is
secure for the duration of the transfer. Restart
the transfer operation.
- Confirm the inverter parameter setting.
- Check that the configuration file is compatible
with the inverter to be configured.
- Check the RJ45 cable and both of its
connectors. Make sure the connection is
secure for the duration of the transfer.
Connect the RJ45 cable.
- Select a file to transfer. - Follow the
procedure for loading configuration files
described on section 5.1.
- Check that the SD card is inserted correctly.
- Check that the SD card is formatted correctly.
- Check if the SD card is locked.
-
22
E6581680
List of cleared
faults codes
Remedy