3.2

Commission modes

In the standard version, the MICROMASTER 440 is fitted with the Status Display
Panel (SDP) (see Figure 3-3) with which it is possible to use the inverter with the
pre-assigned factory settings for a large range of applications. If these factory
settings are not suitable, you can adapt them to suit your equipment conditions
using the Basic Operator Panel (BOP) (see Figure 3-3) or the Advanced Operator
Panel (AOP) (see Figure 3-3). The BOP and AOP are available as options. You
can also adjust the factory settings using the PC IBN tool "Drive Monitor" or
"STARTER". This software is available on the CD ROM which comes with the
documentation of the unit.
ATTENTION
MICROMASTER 440 can only be operated with one of the operator panels BOP
or AOP.
If a BOP-2 panel is used
SDP
Status Display Panel
Figure 3-3
For notes on replacing the operator panels please refer to the corresponding
annexes on page 129 in this manual.
NOTICE
Adjusting the motor frequency 50/60 Hz: The DIP switch to adjust the motor
frequency is located below the I/O board (for removing the I/O board, see annex on
page 135)
The inverter is delivered as follows:
! DIP switch 2:
♦ Off position: European
defaults (50 Hz, kW etc.)
♦ On position: North American
defaults (60 Hz, hp etc.)
! DIP switch 1:
Not for customer use.
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
H z
H z
Basic Operator Panel
Panels available for the MICROMASTER 440 Inverter
will be displayed
50.00
Fn
0
og
P
BOP
Figure 3-4
DIP switch
3 Commissioning
R U N N I N G
f n
P 0 0 0
F =
5 0 . 0
H Z
f l
I = 4 . 8
R P M = 1 5 0 0
p
V = 4 0 0 v
v
1
Fn
menu
0
og
P
AOP
Advanced Operator Panel
DIP Switch for
motor frequency
45