• Ensure there is enough free space in the switchgear cabinet to allow the sheet metal
• Also provide enough free space to add on to the device.
• Equip the switchgear cabinet with struts for stabilizing the installation cut-out. Install struts
• Avoid extreme environmental operating conditions. Protect your device against dust,
• Install the device in such a way that it poses no danger, e.g. by falling over.
• During assembly, please comply with the approved installation positions.
For additional information, refer to the dimension diagrams in the appendix.
3.5.2

Permitted mounting positions

Approval
Certain installation positions are approved for the device.
Figure 3-3
Vertical installation and deviations between +20° and -20° in the given directions is
permitted.
SIMATIC PC Panel PC 677/877, Control Unit
Operating Instructions, Edition 04/2005, A5E00407724-01
cover to be removed. You will otherwise have to remove the device from the switchgear
cabinet or boom when replacing memory or the battery.
where necessary.
moisture and heat.
Notice
If the device is installed in an unapproved position, the licenses expire in accordance with
UL 508 and EN 60950!