Error Diagnostics - Siemens SIMATIC PC BI45 Technical Description

Pc bi45/fi45 pii
Table of Contents

Advertisement

1.7

Error Diagnostics

Error
Power-ON LED does not light up
The "Invalid configuration
information... Press the F1 key for
continue, F2 to run Setup utility"
appears on the screen
The "No boot device available"
appears on the screen
"Keyboard stuck key failure"
message appears
Booting of the PC aborted after
several beeps
Every time a key is pressed, a beep
is heard and no characters appear
Not-ready message when trying to
write to a diskette
Write-protect error when trying to
write to a diskette
"EPROM TSR Interface disabled,
check Power Management"
message
COM1,COM2, LPT1 or MPI/DP
do not respond
<\> key labeling missing
<\> key is not displayed
Mouse not working
Mouse pointer cannot be moved
Mouse pointer moving erratically
Drive cover cannot be opened
SIMATIC PC BI45/FI45 PII, Technical Description
C79000-G7076-C794-03
Cause
PC is switched off
Power supply is not properly
connected
Incorrect configuration data
Buffer battery is low or damaged
There is no boot diskette in the
drive
Wrong hard disk drive set in
SETUP
A key has become blocked
during the system keyboard self-
test
An error has occured during the
system self-test
Keyboard buffer overflow
No diskette has been inserted
Diskette has not been formatted
Diskette write-protect activated
Write-protect hole open on 3.5"
diskette
"Programming Interface" has
been disabled in SETUP
Ports have been disabled in
SETUP
No original keyboard
Wrong keyboard driver is being
used
Trackball does not rotate
No or wrong mouse driver is
used
PS/2 port has been disabled in
SETUP
Trackball dirty
Filter cap not properly fixed
System Unit
Remedy
Check power supply
connections, power cable and
power plug
Press "F2" key, check the
configuration data in SETUP,
enter any default values, and
check error messages in the first
SETUP menu
Use the "Fixed disk function" in
SETUP
Check the keyboard
Restart the system
Check the hardware
<CTRL> <PAUSE>
Insert diskette
Format diskette
Cancel write protection
Enable "Programming Interface"
in SETUP under submenu "FI
Hardware options"
Enable COM1,COM2, LPT1 or
MPI/DP in SETUP under
submenu "FI Hardware
Options."
German keyboard: <ALTGr >
< ß >, or <ALT> <9> <2>
International keyboard: <ALT>
<9> <2>
Load correct keyboard driver
<ALT> <9> <2>
Clean trackball and housing
Load correct mouse driver
Check SETUP settings
Clean trackball and housing
Push filter cap in proper position
1-35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic pc fi45

Table of Contents