Servicing the LowPro
To remove a beacon from the Category II bracket, lift the latch and release
the pressure from the beacon. The beacon will now be able to slide upwards
out of the bracket.
It is not anticipated that the LowPro
cleaning or, rarely, replacement.
Brackets are a key part of the overall beacon system. They hold a beacon
ready for deployment while preventing false alarms.
NOTE: Whenever a beacon is returned for service, it must be accompanied
by the bracket.
10.
Self-Testing the beacon
The RLB-37 beacon may be self-tested as is warranted, up to a maximum of
sixty times in the five-year life of the battery, or once per month for the life of
the battery. Self-Tests can be performed randomly. However, ACR
recommends that you perform the Self-Test on a once per month schedule.
Do not exceed sixty (60) Self-Test cycles limit in the five-year life of the
battery, to conserve the battery for emergency use.
The functional Self-Test is initiated by momentarily
lifting the Activation Switch to a vertical position and
holding it in this position for at least one second and at
most four seconds. A beep indicates the initiation of
the Self-Test sequence. Self-Test will check battery
capacity and perform five functional test sequences as
described in the digital display Appendix.
The last green LED indicates a successful test. If any of the individual tests
fail during Self-Test, there will be two beeps and a red LED flash at the end of
the Self-Test. Self-Test will discontinue at that point.
NOTE: The "beeps" are a very high-pitched tone that some people may not
be able to hear. When performing the Self-Test, you may follow the
messages on the digital display or you may count the green LED flashes.