Contacts and relay coils are connected with the wiring arrow in Connect mode. The
easyE4 device displays the cursor in this mode as a wiring arrow.
Use
wish to create a connection.
Do not position the cursor on the first contact field.
Here the ALT button has a different function (add rung).
Press the ALT button to switch to Connect mode.
Use the
cursor buttons to move the arrow between the contact and coil
fields and use the
Press the ALT button to leave Connect mode.
The easyE4 device closes the mode automatically as soon as you have moved the
arrow to an occupied contact or coil field.
In a rung, the easyE4 device connects contacts and the con-
nection to the relay coil automatically if no empty fields are
between them.
Never wire backwards.
Figure 83: Circuit diagram with five contacts, invalid
When using more than four contacts in series, use one of the 96 M or 128 M markers.
Figure 84: Circuit diagram with M marker relay