Application planning

4.1

Cable glands

The signal cable to the electronic weighing system is fed into the enclosure through an EMC
cable gland. A high level of protection against electromagnetic interference (EMI) is achieved
due to the large area shielding in the cable gland. The cable glands are made of nickel-
plated brass.
The aluminum SIWAREX JB junction box is equipped with plastic cable glands as standard.
The connecting cables of the load cells are fed into the enclosure through plastic cable
glands. The shielding is attached to screw terminals. If electromagnetic interference from the
load cell cables is expected in the system, the plastic cable glands can be replaced with
EMC cable glands. EMC cable glands are available as accessories (Page 39). Maximum
immunity to interference is achieved by the large area shielding layer.
The stainless steel SIWAREX JB junction box is equipped with EMC cable glands as
standard. The connecting cables of the load cells are fed into the enclosure through EMC
cable glands. A high level of protection against electromagnetic interference (EMI) is
achieved due to the large area shielding in the cable gland. The cable glands are made of
nickel-plated brass.
Purchase EMC cable glands in stainless steel from the appropriate suppliers. Note that the
cable glands must be approved for the respective applications. See Service and support
(http://www.siemens.com/automation/service&support)