Power, Thermal, And Acoustics; Power; Power Supply - Dell PowerEdge MX7000 Manual

Hide thumbs Also See for PowerEdge MX7000:
Table of Contents

Advertisement

Power, thermal, and acoustics

Power

Power Supply

The MX7000 Power Supplies will utilize a new front-loading form factor developed for the MX portfolio. Up to six PSUs plug into the
front of the chassis. These mate directly with connectors on the Main DB. The AC connections come from the rear of the chassis
cabling to connections on the PDB. The Platinum PSUs support 3000W output with high line AC input. For low line input the PSUs
will output approximately 1400W. Low line will not be supported at RTS. If low line is ever supported, mixed high line and low line AC
inputs in the same chassis will not be supported. The supplies are set nominally to output 12.2V DC at the output.
Figure 7. PSU indicators
1.
PSU health indicator
3.
DC output status indicator
Table 8. PSU health indicator codes
PSU health indicator
PSU functioning normally
PSU faulty
PSU mismatch
Table 9. AC indicator codes
AC indicator
AC source available
AC source unavailable or
power cable unplugged
Indicator state
Green
Blinking amber
ON for 1 second, and then 5 blinks and OFF (non-repeating cycle).
Indicator state
ON
OFF
2.
AC supply status indicator
9
23