ACR Electronics Nauticast Y1-03-0212 Installation Manual page 45

Acr electronics automatic identification system installation manual
Table of Contents

Advertisement

Select Submenu 3 "Persons on Board" with cursor button [Up] & [Down] or by pressing Nr. 2
on the keyboard.
Note:
The total number of persons on board will be calculated automatically. In "High Seas" mode
this sum will be used for the AIS messages.
How to use this menu to transfer PoB – information will be described in detail in the User Manual.
Select Submenu 4 "Destination" with cursor button [Up] & [Down] by pressing Nr. 4 on the
keyboard.
Select between mask input and direct input of the destrination string.
Mask input:
Scroll the Data Fields with [Enter] and input the UN destination codes as well as the ETA
(estimated time of arrival) data.
Save the new settings by pressing [Save], and return to the Main Menu Screen by pressing
[Exit]. Press [Back] to return to the Main Menu without saving any changes.
Installation Manual
o
o
N 1
18' E
0
12' |1>0.01|2>1.30|3>1.80nm
************* PoB Settings *************
Crew Members:0-254 (255 = unknown = default)
Passenger
:0-8190(8191= unknown = default)
S. Personal :0-254 (255 = unknown = default)
--------------------------
Total
:nnnn
Members
M6: Send addressed PoB Message
M7: Broadcast PoB Message
----------------------------------------
Num|
Save
|Addressed |Broadcast | Exit
o
o
N 1
18' E
0
12' |1>0.01|2>1.30|3>1.80nm
************* Destination***************
use mask [*]/[ ] input string
UN Country
:NL
UN Location
:DOR
Fairway section:02552
Terminal code
:LEUVE
Fairway hector :00000
ETA(MMDDhhmm)
:10/31 10:05
----------------------------------------
|
Save
|
|
| Exit