Performance With Heatsink At The Back With 500 W - Infineon D2 PAK User Manual

Full-bridge converter for ups
Table of Contents

Advertisement

Full-bridge converter for UPS
2
2
D
PAK/ D
PAK-7 kit
UG_1801_PL16_1802_225559
4
5
6
7
8
Average
Stdev
Figure 15
Back thermal image after 1 hour
1.8.2

Performance with heatsink at the back with 500 W

As shown in Figure 17, both case temperature readings at the resistor (78°C) and PCB location A (49°C) are higher
than those (64°C and 44°C) with same parts at 420 W in Figure 15 and also higher than the (69°C and 46°C) with
2
D
at 420 W in Figure 12. The middle of the heatsink temperature reads 55°C, as shown in Figure 18, and is 5°C
2
higher than that with D
parts with 420 W, as shown in Figure 13. The average efficiency with D
shown in Table 6 is 97.0 percent, which is 0.4 percent higher than that with 420 W, shown in Table 4.
User Guide
96.5
96.5
96.6
96.7
96.6
96.6
0.1
15
4
0.65
5
0.67
6
0.65
7
0.65
Average
0.65
Stdev
0.01
B: 43°C
47°C
7 0 .0 °C
60
40
20
2 0 .0 °C
2
7-pin parts
Revision 1.0
2018-03-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

D2 pak-7

Table of Contents