GEnEraL
DrYEr SaFETY
iMPOrTanT
Electrostatic Discharge (ESD)
Sensitive Electronics
ESD problems are present everywhere. ESD may damage or weaken the
electronic control assembly. The new control assembly may appear to
work well after repair is finished, but failure may occur at a later date due
to ESD stress.
• Use an anti-static wrist strap. Connect wrist strap to green Earth
connection point or unpainted metal in the appliance
-OR-
Touch your finger repeatedly to a green Earth connection point or
unpainted metal in the appliance.
• Before removing the part from its package, touch the anti-static bag to a
green Earth connection point or unpainted metal in the appliance.
• Avoid touching electronic parts or terminal contacts; handle electronic
control assembly by edges only.
• When repackaging failed electronic control assembly in anti-static bag,
observe above instructions.
1-1