Remove Central Control Unit (Ccu) - Maytag MDG25PN Service Manual

Commercial high efficiency single load gas and electric dryers 50hz models
Hide thumbs Also See for MDG25PN:
Table of Contents

Advertisement

rEMOvE cEnTraL cOnTrOL uniT (ccu)

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Open dryer top (See page 4-3).
2.
Disconnect CCU to UIC Rast connector.
3.
Disconnect P14 wire connector by
depressing the tab and pulling Connector off
the control.
4.
Disconnect P8 wire connector by
depressing two locking tabs and pulling
connector off the control.
5.
Disconnect P9 wire connector by pulling
connector off the control.
1/4" Hex
Head Screw
6.
7.
8.
9.
CCU Wire
Connectors
10.
4-9
Disconnect K2 relay wire connector by
pulling connector off the control.
Remove the 1/4" hex head screw that
secures CCU to the bracket.
Turn bracket over and press the locking tab
on the bottom of the bracket.
Slide the CCU sideways to release tabs
from slots and lift CCU off the bracket.
CCU Locking
Tab
Use a pair of pliers to squeeze three
Christmas tree clips and push them through
to the front of the bracket to release wire
ties from the bracket and remove it.
Christmas
Tree Clips

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mde25pnMdg25pdMde25pdMdg22pnMde22pdMde22pn ... Show all