6 times
Internal
temperature error
7 times
Ink absorber full [5B00,
No wetting
liquid
8 times
Print head
temperature rise
error
Reactor error
9 times
EEPROM error
10 times
VH monitor
error
11 times
Carriage lift
mechanism error
feeding from the rear tray.
[5400] The internal temperature is
not normal.
The ink absorber is supposed
5B01]
to be full.
Error codes:
5B00: Overseas
5B01: Japan (In
EEPROM information
print, "5B00" is printed
instead of "5B01.")
[5250] The wetting liquid is used up. (1) Part replacement:
[5200] The print head temperature
exceeded the specified value.
[B300] A hardware error occurred in
supplying Clear ink.
[6800,
A problem occurred in
6801]
reading from or writing to the
EEPROM.
[B200] The VH (print head drive
voltage) is out of the
specified value.
[5110] The carriage did not move up
or down properly.
16 / 53
- ASF unit
- Logic board
(1) Cable connection
(2) Part replacement:
- Spur base unit
- Logic board
- Print head
(1) Ink absorber condition
(2) Part replacement:
- Ink absorber kit
(3) Ink absorber counter value in the
EEPROM:
reset the ink absorber counter.
- Blade cleaner unit
(2) Wetting liquid counter value in the
EEPROM:
reset the wetting liquid
counter.
(1) Print head condition
(2) Cable connection
(3) Part replacement:
- Print head
- Logic board
(1) Part replacement:
- Valve unit
- Sheet feed unit
- Logic board
(1) Part replacement:
- Logic board
(1) Part replacement:
- Print head and logic board
(Replace them at the same
time.)
- Carriage unit
- Power supply unit
(1) Foreign material or paper debris
that obstructs the carriage
movement:
remove foreign material.
(2) Part replacement:
- Carriage lift gear unit
- Carriage lift sensor
- ASF unit