Silex technology PRICOM SX-3700WB User Manual

Silex pricom sx-3700wb users manual

Advertisement

Quick Links

2. PRICOM SX-3700WB
This product is a wireless USB device server that will serve USB type peripheral equipment
(a printer, scanner etc.). By using the bundled PRICOM Monitor SX, it is possible to view the
state of the connected printer via a network. In addition it is possible, by using the bundled
PRICOM USB Utility, to share a scanner as a network scanner.
- Windows 2000, Windows XP, or Windows Server 2003 is required to use the network scanning
function.
TIP
- Only one USB device can be connected at a time. The USB device must be connected directly
to this product
- Refer to our web page ( http://www.silex.jp/ ) for the most up to date information.
NOTE
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
EN55022 Class-B
EN55024
PRICOM SX-3700WB
Users Manual SX2
2-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRICOM SX-3700WB and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Silex technology PRICOM SX-3700WB

  • Page 1 Users Manual SX2 2. PRICOM SX-3700WB This product is a wireless USB device server that will serve USB type peripheral equipment (a printer, scanner etc.). By using the bundled PRICOM Monitor SX, it is possible to view the state of the connected printer via a network. In addition it is possible, by using the bundled PRICOM USB Utility, to share a scanner as a network scanner.
  • Page 2 - Temperature: +10 C +35 C - Humidity: 20% to 80%RH (no dewing) Storage Environment - Temperature: -10C to 50C - Humidity: 20% to 90%RH (no dewing) Electric current 5V +- 5% 1.0A VCCI Class-B FCC Class-B EN55022 Class-B EN55024 PRICOM SX-3700WB...
  • Page 3: Part Name And Function

    Lights when an OldAdHoc mode network connection is flashed. Lights when an AdHoc mode network connection is established. Lights when an Infra. mode network connection is established. Status LED (Orange) Flashes during data transfer. PRICOM SX-3700WB Bottom Status LED (Orange)Ethernet Address Status LED...
  • Page 4 - Do not turn off the power to this product while it is initializing to factory default. - When this product is turned on again after factory default is completed, do not push the pushbutton switch. PRICOM SX-3700WB Link LED...
  • Page 5 5. Hold the push switch (for about 30 seconds). The self test and configuration will then begin. - Do not turn off the printer until the printing of self-test/configuration settings has finished. - The printer must have and internal font for the self-test/configuration settings to print. PRICOM SX-3700WB...
  • Page 6: How To Connect

    - Do not disconnect the USB cable during printing, scanning or reading/writing from a memory card. - After turning on this product or connecting the USB cable, printing will proceed according to priority. PRICOM SX-3700WB [ Example ] Type B...
  • Page 7: Other Functions

    HTTP 1.0(RFC1945) and HTML 2.0(RFC1866). - If you use the Web browser function, you should configure the IP address of this product and enable the TCP/IP protocol. - An IP address must be assigned prior to using the Web browser. PRICOM SX-3700WB...
  • Page 8 “txt” file will print. The server will print the e-mail and then the name of the attached file if the file is not a “txt” file - The printer must send an error notice to the USB port in order to use SMTP. PRICOM SX-3700WB...
  • Page 9: Hardware Specification

    Users Manual SX2 Specification Hardware Specification 32bit RISC CPU Memory :8MByte FlashROM :1MByte Network Interface IEEE802.11b compatible CF card USB Interface Type A port Other Push switch :Status(Orange), Link(Green), Infra(Green) PRICOM SX-3700WB...
  • Page 10: Software Specification

    NetBEUI/NetBIOS: SMB, NetBIOS AppleTalk: AppleTalk Phase2, ELAP, AARP, DDP, AEP, NBP, RTMP, ZIP, ATP, PAP PRICOM SX-3700WB ARP, RARP, ICMP, IP, IPv6, ICMP6 TCP, UDP LPD, TELNET, BOOTP, SNMP, HTTP, DHCP, IPP, #9100, DNS, NetBIOS, FTP, POP3, SMTP, SNTP 2-10...
  • Page 11: Using Wireless Communication

    However, when they approximate this product, sound or image noise can happen. If there is reinforced concrete/metal between wireless devices, they may not connect. This product can connect through wood or glass, but can have trouble communicating through reinforced concrete/metal. PRICOM SX-3700WB 2-11...
  • Page 12 (example: create the wall). 2.4 DS 2.4 : The frequency of this device is 2.4Ghtz. DS : The modulation used is DS. PRICOM SX-3700WB : The range of interference is (<=40m). : Different channels can be used to avoid interference. 2-12...
  • Page 13 Users Manual SX2 <AdHoc mode> Each wireless product connects directory. Connect this product to the USB device using a USB cable. The PC connects directly to our product in AdHoc mode. NOTE PRICOM SX-3700WB 2-13...
  • Page 14 - The following are the two ways to put this product into Infrastructure mode 1. Set the mode to be Infrastructure during the configuration. NOTE 2. After boot, hold down the push switch. PRICOM SX-3700WB Connect this product to the USB device using a USB cable. 2-14...

This manual is also suitable for:

Sx2

Table of Contents