Dimension L (2.7.5.); Transducer Selector (2.7.6.); Inflow/Discharge Adjust (2.7.7.) - Siemens HydroRanger 200 HMI Operating Instructions Manual

Sitrans ultrasonic controllers
Hide thumbs Also See for HydroRanger 200 HMI:
Table of Contents

Advertisement

8.6.7.5

Dimension L (2.7.5.)

Enters the length of the cylindrical section of a horizontal parabolic end vessel. For
illustrations, see Vessel shape (2.7.2.) (Page 186).
Dimension L as used in Vessel shape (2.7.2.) (Page 186).
Index
Values
Related
Enter the tank length (excluding both end sections) if Vessel shape (2.7.2.) (Page 186) =
parabolic ends.
8.6.7.6

Transducer selector (2.7.6.)

Sets the transducer index for all parameters applicable to this sub-menu.
8.6.7.7

Inflow/discharge adjust (2.7.7.)

The method used to calculate the volume pumped, for pumped total [Sensor Mode (2.1.3.)
(Page 163) = Pump Totalizer].
Index
Options
Related
HydroRanger 200 HMI
Operating Instructions, 06/2018, A5E36281317-AC
Level
Range: 0.000 ... 99.000 m or equivalent, depending on Units (2.1.1.) (Page 162)
Preset: 0.000
Vessel shape (2.7.2.) (Page 186)
Single-point model
Global
Based on Pump Cycle
No adjustment
*Based on Rate Estimation
Sensor mode (2.1.3.) (Page 163)
Rate filter (2.3.5.) (Page 175)
Rate filter time (2.3.6.) (Page 175)
Rate filter distance (2.3.7.) (Page 175)
Rate (2.3.) (Page 172)
Parameter reference
8.6 Setup (2.)
Dual-point model
Transducer
189