3. Remove plastic cover from gas pressure regulator cap.
4. Turn gas pressure regulator cap counterclockwise with
a
5
/
" (1.6 cm) combination wrench to remove.
8
NOTE: Do not remove the spring beneath the cap.
A
B
C
A. Plastic cover
B. Gas pressure regulator cap with solid end facing out
C. Gas pressure regulator cap with hollow end facing out
D. Washer
E. Gas pressure regulator cap
5. Turn over the gas pressure regulator cap and reinstall on
regulator so that the hollow end faces out and the marking
" LP" is facing the direction shown in the above drawing.
6. Replace plastic cover over gas pressure regulator cap.
To Convert Surface Burners (Natural Gas to LP Gas)
1. Remove burner cap.
2. Remove the burner base.
A
A. Igniter electrode
B. Burner cap
C. Gas tube opening
D. Burner base
3. Apply masking tape to the end of a
help hold the gas orifice spud in the nut driver while
changing it. Press nut driver down onto the gas orifice spud
and remove by turning it counterclockwise and lifting out.
Set gas orifice spud aside.
B
A
C
A. Igniter electrode
B. Orifice spud
C. Orifice spud holder
D. Screws
14
Side view before
D
E
Side view after
B
C
D
9
/
" (7 mm) nut driver to
32
D
4. Remove the orifice spuds shipped in the literature package
in the oven. Gas orifice spuds are stamped with a number
and have a groove in the hex area. Replace the Natural gas
orifice spud with the correct LP gas orifice spud.
A. LP groove
Refer to the following chart for correct LP gas orifice spud
ratings and to spud holder card for proper placement.
LP Gas Orifice Spud Chart for Surface Burners
Burner Rating/
Size (mm) ID number
Type
13,500 BTU/Ultra 1.06
7,500 BTU/Semi
0.80
4,500 BTU/Auxi
0.61
NOTE: Refer to the model/serial/rating plate located on the oven
frame behind the top left-hand side of the oven door for proper
sizing of spuds for each burner location.
5. Place Natural gas orifice spuds in the orifice spud bag.
IMPORTANT: Keep the Natural gas orifice spuds in case
of reinstallation with Natural gas.
6. Replace the burner base.
7. Replace burner cap.
8. Repeat steps 1 to 7 for the remaining burners.
To Convert Oven Bake Burner (Natural Gas to LP Gas)
1. Remove the oven racks and the oven door. See the "Oven
Door" section.
2. Remove 2 screws and washers at the rear of the oven
bottom.
3. Lift the rear of the oven bottom up and back until the front
of the panel is away from the front frame. Remove from oven
and set it aside on a covered surface.
A
A. Screws
B. Oven bottom
4. Remove 2 screws from the bake burner.
A
Placement
106
LF/FR
080
RR/RF
061
LR
B