This message appears if Self-Test has passed. The display indicates that the external GPS did
not update its coordinates during Self-Test.
NOTE: If external GPS data cannot be acquired, typically due to the external GPS not having
achieved a good fix, it does not affect the pass status of Self-Test. Self-Test requires GPS engine
readiness but does not require that the GPS obtain coordinates.
SELF
If one of the six tests fails, the system advises you that Self-Test has failed.
SEE
This message appears if Self-Test failed. The system advises you to refer to this Product Support
Manual (User Book) for information on what to do and who to contact.
SEEK
This message appears if Self-Test failed. The system advises you to seek service from an
authorized Service Center. Not only should the beacon be fixed immediately, it also should not be
placed into service until the problem is addressed.
NOTE: "SEEK FIX NOW" has the same meaning as "FIX NOW"
BATT
This message appears if Self-Test has passed, but the battery is low. Take the beacon to an
authorized Service Center for a battery replacement.
NOTES regarding Self-Test logic:
1.)
When one of the tests fail, the system bypasses the remaining tests
and goes to SELF-TEST FAIL
2.)
The only exception to #1 is that if the battery fails, the other tests are
still performed. The system will tell the user if there are other system failures
by flashing SELF-TEST FAIL. If there are no failures other than battery life,
the system flashes SELF-TEST PASS, then BATT LOW.