Command Interface
5.2.28
Write_AS-i_Slave_Parameter_String
Purpose
With this call, a parameter string complying with AS-i slave profile 7.4 can be sent
to the AS-i master that passes on the string to the AS-i slave address specified in
the send buffer.
With this call, a send buffer with a maximum of 223 bytes is transferred to the AS-i
master. The actual number of parameter bytes to be sent to the AS-i slave is
calculated by the AS-i master from byte 2 of the send buffer (number of parameter
bytes).
The information in the string is not evaluated by the AS-i master and is passed on
to the AS-i slave transparently.
As long as the string transfer is active, there is no user/analog data exchange with
the addressed AS-i slave.
Structure of the Job Data in the Send Buffer
Bank
Byte
2
2
2
2
2
...
...
...
Maximum value for n=220
Structure of the Job Data in the Receive Buffer
Bank
Byte
2
0
2
1
5-54
0
1
2
Number of parameter bytes
3
4
...
...
...
Echo of the command number: 40
Meaning
40
H
Slave address
String byte (1)
String byte (2)
.....
String byte (n–1)
String byte (n)
Meaning
H
Command status