TC65 JAVA User's Guide
Strictly confidential / Released
5.9.3.1
Plain Serial Interface
Scenario: A device is connected to ASC0 (refer to 4.2.4). The Java application must handle
data input and output streams. A simple Java application (with only one thread) which loops
incoming data directly to output, reaches data rates up to 180kbit/s. Test conditions:
hardware flow control enabled (<autorts> and <autocts>), 8N1, and baud rate on ASC0 set
to 230kbaud (-> theoretical maximum: 184kbit/s net data rate).
5.9.3.2
Voice Call in Parallel
Same scenario as in section 5.9.3.1, but with a voice call added. The application reflects
incoming data directly to output and, additionally, handles an incoming voice call. The data
rates are also up to 180kbit/s. Test conditions: same as in Sect. 5.9.3.1.
Figure 14: Scenario for testing data rates on ASC1 with a voice call in parallel
TC65 JAVA User's Guide_V05
Figure 13: Scenario for testing data rates on ASC1
Page 31 of 90
TC65
Java
application
(looping data)
TC65
Java
application
(looping data)
s
26.09.2005