Your network system will generate a large number of error messages as
a result of the faulty connection(s). As these messages are taking up
bandwidth, the performance of your network may become very slow.
The occurrence of a problem in the cabling system can be diagnosed with
the remote statistics found on "Remote" tab in the monitor mode of the
RLM Manager.
1. Select
statistics for the Ethernet interface.
2. Compare the number of
.
When the number of "In errors" is 1% or more of the "Bridge in
packets" , this may indicate a cabling problem.
3. Compare the number of packets
When the number of "Out errors" is 1% or more of the "Bridge out
packets" , it is likely that there is a cabling problem.
4. Compare the number of
When the number of "Out carrier sense errors" is 1% of the
"Bridge out packets" or the value of the "Out carrier sense errors"
increases too rapidly, this indicates insufficient space on the
network due to a backbone overload, or faulty cabling.