  • Page 1 (IEIA-152) Installation instructions...
  • Page 2 (IEIA-152)
  • Page 3: Table Of Contents

    Installation instructions Contents Connection in TN-S/C or TT network Mounting and electrical installation Circuit diagram Electrical and functional testing Technical data Very important information Instructions which particularly relate to safety 20.03.2018 • Version 1.0...
  • Page 4: Connection In Tn-S/C Or Tt Network

    (IEIA-152) Connection in TN-S/C or TT network Installation of the eStation is only permitted on a metered connection of an existing sub-distribution. Installation in the IT network is prohibited! Connection in TN-S network: eHZ meter foundation earth electrode...
  • Page 5 Installation instructions Connection in TT network: eHZ meter construction foundation earth earth electrode electrode eHZ meter Figure 3 sealable Cable for energy transmission pursuant to DIN VDE 18015 ΔU max < 3%...
  • Page 6: Mounting And Electrical Installation

    (IEIA-152) Mounting and electrical installation 1. Preparation 3. Installation of ram protection • Excavation of pit for concrete base • Fixing of ram protection with bolts on concrete base • Filling of pit floor with sand, preparation of blinding layer...
  • Page 7 Installation instructions 5. Installation of charging station Ensure during fitting that both cylinders can • Mounting of charging station on ram lock independently of each other. protection • Fixing of charging station with ram protection using 4 screws 6. Electrical connection of charging station to the supply line •...
  • Page 8: Circuit Diagram

    (IEIA-152) Circuit diagram eStation circuit diagram Plug lock Plug lock Creation date: 29.03.2012 Circuit diagram eStation Alteration date: Draughtsman: Heßelmann Peer reviewed: Scholtz Alteration: Date of examination: 28.03.2012...
  • Page 9: Electrical And Functional Testing

    Electrical test Electrical tests/measurements must be undertaken in accordance with national standards (including VDE guidelines). Measurements to be undertaken are taught during innogy training. The following are examples of measurements: • Checking of existing TN network/TT network system • Measurement of tripping times of FI type B (e.g. Fluke 1654B multifunction tester) •...
  • Page 10: Technical Data

    (H x W x D) 1,460 x 300 x 200 mm Installation: Free-standing on an appropriate concrete base or on a viable concrete base using a mounting frame Weight: innogy eStation: ~ 42 kg Ram protection: ~ 18 kg Foundation: ~ 100 kg Protection class IP54 Temperature range −25 °C to +40 °C...
  • Page 11 Installation instructions Installation instructions...
  • Page 12 SE Flamingoweg 1 44139 Dortmund Germany emobility@innogy.com innogy.com/emobility...