Page 1
To minimize the risk of serious injury, death or damage, before installing or first using this equipment, read Instruction Manual and all safety labels and follow all safety instructions and precautions. Save manual for future reference. Ver la versión en español de este manual en www.frogproducts.com/product/frog-leap-twin...
TABLE OF CONTENTS FROG Leap Twin Infuzers Introduction Notes and Safety Information Safety Labels on Infuzers ® Installation Tips to Ensure Proper Performance Base Flex-Hose Installation Hard-Plumbed Installation Step 1: Preparing the Pool 9-10 Step 2: Putting the System to Work...
FROG Leap Mineral System consists of the FROG minerals silver chloride and carbonate used in conjunction with 0.5 ppm chlorine. The FROG Leap Anti-Bac Mineral Pac must be used in conjunction with the FROG Leap Torpedo Pac (EPA Reg. No.: 53735-2), an EPA registered chlorine pool product or a chlorine delivery device.
Notes and Safety Information General Notes These instructions do not provide for every possible contingency These instructions contain information for the safe and proper operation of these Infuzers. Observe the following principles: that might be encountered in connection with installation, opera- •...
Reveille, FROG Leap Depth Charge and FROG Leap ALL-OUT) in the FROG Leap Twin Infuzers. Never use bulk chemicals. a To prevent the build up of gas pressure in the FROG Leap Twin Infuzers, be sure the pool return line valves are open – except when opening or servicing the unit.
The best option is to have two lines. One line with pump, filter, heater and hours per day or less than 6 hours per FROG Leap Twin Infuzers and a second line with a separate pump for the day on high speed, you must bleed the in-floor cleaning system (filter optional).
Sealant Two hose adapters 1½” x 1½” x 1¼” Screw adapters into each end of the FROG Leap Twin Apply pipe thread tape or Two Sections of 1½” or Infuzers. Hand tighten. Finish tightening by turning 1 to 2 sealant to the threaded end 1¼”...
FROG Leap Anti-Bac Mineral 1½” Male Adapter Pac and FROG Leap Torpedo Pac. (slip x MPT) Screw adapters into each end of FROG Leap Twin Infuzers following Measure the distance 2” Female between outside directions for a male adapter or a female adapter. Hand tighten.
Step 1: Preparing the Pool Make sure the pool has adequate Check for metals in the pool such circulation. The total volume of pool as iron or copper. Before attempting water must completely circulate Metal water balance, these should be through the pump and filter at least removed.
Page 10
Chlor catridge • Never use fast dissolving chlorine tablets, liquid If lighter color, If darker color, Active Chlorine bleach, or calcium hypochlorite in the FROG Leap turn cartridge turn cartridge Look at the Total Alkalinity reading first. Adjustments Twin Infuzers.
If using standard chlorine shocks do not add in or near shorter. After that time, you the skimmer or into the FROG Leap Twin Infuzers as it will hear the spent media could damage equipment, risk potential explosion or...
1a. Set FROG Leap Twin Mineral Infuzer control dial to Setting 10. No further adjustments are needed. 1b. Set FROG Leap Twin Chlorine Infuzer control dial by matching up the parameters of your pool on the chart below. THIS IS A STARTING POINT ONLY and may need to be adjusted to fit your individual pool needs.
OK too. WARNING DANGER To prevent the build up of gas pressure in the FROG Leap • Never add any other types of chlorine, pH adjusters, Twin Infuzers, be sure the pool return line valves are open shock treatments or algaecides through the skimmer.
Open FROG Leap Twin Mineral Infuzer cap. Check the top of the box and back label of product to make sure you have the correct FROG Leap Anti-Bac Mineral Pac to fit your FROG Leap Twin Mineral Infuzer. Replace Every Season...
Using FROG Leap Pool Wake Up! FROG Leap Depth Charge is a one time start-up product used to rid the water of all contaminants. FROG Leap Reveille - also used at start up, sets the chlorine residual REVEILLE to help find the proper dial setting for maintaining up to 50%* less 90-DAY chlorine.
Using FROG Leap ALL-OUT for an Algae-Protection Guarantee If you are not using FROG Leap ALL-OUT, refer to page 17 for using the For a preventive dose add: FROG Leap Torpedo Pac. See FROG Leap ALL-OUT product labeling for • One FROG Leap ALL-OUT for pools up to 15,000 gallons.
FROG Leap Torpedo Pac is required to Never use fast dissolving chlorine tablets, liquid bleach, assure up to 50% reduction in chlorine or calcium hypochlorite in the FROG Leap Twin Infuzers. use*. FROG Leap Torpedo Pac sold separately. (EPA Reg. No. 53735-2) WARNING ®...
Page 18
Continue... Using FROG Leap Torpedo Pac The chlorine pac container is Insert FROG Leap made of HDPE plastic. Non- Torpedo Pac into FROG refillable container. Do not Leap Twin Chlorine reuse or refill this container. Infuzer, lining up the WE RECYCLE Offer for recycling if available.
You will hear spent media inside, however it is no longer effective. Remove the FROG Leap Torpedo Pac. If it still contains chlorine, wrap in plastic bag and store in shed or cool, dry, well-ventilated location away from children, pets, cars, motorcycles, or anything metal that can rust, pit, etc.
3.0 ppm, remove the Torpedo Pac lowest possible setting, consider relief valve is loose or missing and What do I do from the FROG Leap Twin Chlorine decreasing the circulation time. replace. It is a clear plastic piece if I am over...
6, 7, 8, 10 11 & DETAIL OF EACH 9 or 10 INFUZER SILICONE LUBRICANT REPLACEMENT parts for FROG Leap Twin Infuzers INCLUDED with FROG Leap Twin Infuzers REF. # DESCRIPTION QTY. INCLUDED REF. # PART NO. DESCRIPTION 1 & 3...
Remove old O-ring. Center of locking pin Top half of groove Place new O-ring in bottom In the back of the FROG Leap half of groove. Twin Infuzers depress center of locking pin with a finger and pull pin out of dial.
FROG Leap Twin Infuzers Two-Year Limited Warranty Register your product online today to extend your FROG Leap warranty to lifetime. frogproducts.com/reg King Technology, Inc. will warrant this unit with a complete replace- 3. Any express warranty not provided for herein, and any remedy...
Need help?
Do you have a question about the Twin and is the answer not in the manual?
Questions and answers