PolyScience Histology Freeze Plate Operator's Manual
PolyScience Histology Freeze Plate Operator's Manual

PolyScience Histology Freeze Plate Operator's Manual

Fast-freezing surface

Advertisement

Quick Links

Operator's Manual
Histology Freeze Plate
110-825
06-17-11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Histology Freeze Plate and is the answer not in the manual?

Questions and answers

Summary of Contents for PolyScience Histology Freeze Plate

  • Page 1 Operator’s Manual Histology Freeze Plate 110-825 06-17-11...
  • Page 2: Table Of Contents

    Table of Contents Introduction ..............................2 General Safety Information ........................2 Safety Recommendations ......................... 3 Unpacking..............................3 Package Contents ............................. 3 Controls and Components......................... 4 Setup ................................5 Location ..............................5 Electrical Power............................5 Operation ..............................5 Routine Maintenance ..........................6 Cleaning ..............................
  • Page 3: Introduction

    When installed, operated, and maintained according to the directions in this manual and common safety procedures, your Histology Freeze Plate should provide safe and reliable operation. Please ensure that all individuals involved in the installation, operation, or maintenance of the Histology Freeze Plate read this manual thoroughly prior to working with the unit.
  • Page 4: Safety Recommendations

    Unpacking Your Histology Freeze Plate is shipped in a special carton. Retain the carton and all packing materials until the unit is completely assembled and working properly. Set up and run the unit immediately to confirm proper operation.
  • Page 5: Controls And Components

    Controls and Components Working surface Freeze Plate Cover Ventilation openings Power Switch / Circuit Breaker Air filter access (on bottom of unit) IEC electrical connection 110-825...
  • Page 6: Setup

    Electrical Power An IEC power cord is provided with the Histology Freeze Plate. It should be attached to the receptacle on the rear of the enclosure. Make sure that the power outlet used for the Histology Freeze Plate is properly grounded and matches the voltage and frequency of your unit.
  • Page 7: Routine Maintenance

    Pure grain alcohol may also be used to clean the working surface during operation. The Histology Freeze Plate can be cleaned using a mild detergent. Be sure to turn electrical power to the unit OFF and allow working surface to return to ambient temperature before cleaning.
  • Page 8: Technical Information

    Technical Information Performance Specifications Peak Working Temperature: -34.4°C (-30°F) Working Surface Dimensions: 14.5 x 9.4 inches (36.8 x 23.8 cm) Overall Dimensions (L x W x H): 15.9 x 18.4 x 10.5 inches (40.3 x 46.7 x 26.7 cm) Shipping Weight: 76 lbs (34.4 kg) Electrical Requirements: 120V, 60Hz, 6.5A...
  • Page 9: Service And Technical Support

    Service and Technical Support If you have questions regarding your Histology Freeze Plate or it fails to operate properly, contact the supplier from whom the unit was purchased. Have the following information available for the customer service person: Model, Serial Number, and Voltage (from back panel label) •...