REPLACING THE I/O MODULES
I/OLINK series model
Product
Model name
AJ55TB32-8DR
(when negative common
type is used)
AJ55TB32-16DR
I/O module
(when positive common
type is used)
AJ55TB32-16DR
(when negative common
type is used)
AnyWire DB A20 series alternative model
Model name
(1) External wiring: Changed
(2) Number of modules: Changed (Two modules are required.)
(3) Program: Changed
(4) Specifications:
(Input part)
Rated input voltage: Not changed
Rated input current: Not changed
ON voltage/ON current: Changed
OFF voltage/OFF current: Changed
Input resistance: Not changed
A20SB-04US
(Output part)
+ A20PB-04RS
Rated load voltage: Changed (The voltage that can be used is equivalent.)
Rated load current: Not changed
Maximum switching frequency:
Changed (3600 times/hour  20 times/minute)
(5) Functions: Changed
(Input part)
Wiring: 3-wire  2-wire
A positive common type cannot be used.
(Output part)
4 points/common  All points independent
(1) External wiring: Changed
(2) Number of modules: Changed (Two modules are required.)
(3) Program: Changed
(4) Specifications:
(Input part)
Rated input voltage: Not changed
Rated input current: Not changed
ON voltage/ON current: Changed
OFF voltage/OFF current: Changed
A20SB-08UD
Input resistance: Not changed
+ A20PB-08RS
(Output part)
Rated load voltage: Changed (The voltage that can be used is equivalent.)
Rated load current: Not changed
Maximum switching frequency:
Changed (3600 times/hour  20 times/minute)
(5) Functions: Changed
(Input part)
A negative common type cannot be used.
(Output part)
8 points/common  All points independent
(1) External wiring: Changed
(2) Number of modules: Changed (Two modules are required.)
(3) Program: Changed
(4) Specifications:
(Input part)
Rated input voltage: Not changed
Rated input current: Not changed
ON voltage/ON current: Changed
OFF voltage/OFF current: Changed
A20SB-08USD-1
Input resistance: Not changed
+ A20PB-08RS
(Output part)
Rated load voltage: Changed (The voltage that can be used is equivalent.)
Rated load current: Not changed
Maximum switching frequency:
Changed (3600 times/hour  20 times/minute)
(5) Functions: Changed
(Input part)
A positive common type cannot be used.
(Output part)
8 points/common  All points independent
Remarks (restrictions)