2
PERFORMANCE SPECIFICATIONS COMPARISONS
*1
The transmission cycle time of the AnyWire DB A20 master module differs depending on the number of transmission points
setting or the transmission clock. For details, refer to the following table.
Max. number of transmission
points setting
64 points (32 points × 2)
128 points (64 points × 2)
256 points (128 points × 2)
384 points (192 points × 2)
512 points (256 points × 2)
640 points (320 points × 2)
768 points (384 points × 2)
896 points (448 points × 2)
1024 points (512 points × 2)
2048 points (1024 points × 2)
Transmission cycle time (ms)
125kHz
31.3kHz
(50m)
(200m)
0.42
1.7
0.7
2.7
1.2
4.8
1.7
6.8
2.2
8.9
2.7
10.9
3.2
13.0
3.8
15.0
4.3
17.1
8.4
33.4
7.8kHz
2kHz
(1km)
(3km)
6.8
24.8
10.9
40.7
19.1
72.4
27.3
104.2
35.5
135.9
43.6
167.6
51.8
199.4
60.0
231.1
68.2
262.9
133.8
516.8