5
Remove the lamp unit.
• Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the
arrow. At this time, keep the lamp unit
horizontal and do not tilt it.
6
Insert the new lamp unit.
• Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
7
Replace the lamp unit cover.
• Align the tab on the lamp unit cover (1)
and place it while pressing the tab (2)
to close it. Then tighten the user ser-
vice screw (3) to secure the lamp unit
cover.
Info
• If the lamp unit and lamp unit cover are not
correctly installed, the power will not turn
on, even if the power cord is connected to
the projector.

Resetting the Lamp Timer

Reset the lamp timer after replacing the lamp.
1
Connect the power cord.
• Plug the power cord into the AC socket
of the projector.
2
Reset the lamp timer.
• While simultaneously holding down
and
on the projector, press
and
on the projector.
• “LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
Info
• Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.
Handle
Securing screws
3
1
2
User service screw

AC socket