2.4

Cases that Require Configuration

If any of the following cases are applicable, operate in System Utility to change parameters from the factory
preset. Other than cases described below, do not change the settings. The catalog of parameters in System
Utility and the factory presets can be found in Chapter 2 (1. System Utilities) of Maintenance Guide.
Category
Settings to
Items to be set at all
be saved in
times
the user
default
Setting up the Time
Format in accordance
with your OS
If you use the
ESMPRO/ServerAgent
Service
Description
Set to Allow Operation with Critical Fan
Failure at System Configuration >
BIOS/Platform Configuration (RBSU) >
Advanced Options > Fan and Thermal
Options > Fan Failure Policy.
Set System Configuration > BIOS/Platform
Configuration (RBSU) > System Options >
USB Options > Internal SD Card Slot to
Disabled.
・If you use Windows
Set to Local Time at System Configuration >
BIOS/Platform Configuration (RBSU) >Date
and Time - Time Format. (Included in line 16)
・If you use Linux
Set System Configuration > BIOS/Platform
Configuration (RBSU) > Date and Time -
Time Format to Coordinated Universal
Time(UTC).
・If you use another OS
Set up following the pre-install checklist in the
installation guide of your OS.
Set to Disabled at System Configuration >
BIOS/Platform Configuration (RBSU) >
Advanced Options > Fan and Thermal
Options > Thermal Shutdown.
Express5800/T120h User's Guide
To be changed
2. System Utility
(1/4)
Remark
At the time of shipment,
Fan Failure Policy is set to
Allow Operation with
Critical Fan Failures.
At the time of shipment,
Internal SD Card Slot is
set to Disabled.
Set up following the
pre-install checklists in the
installation guide below.
For Windows: Chapter 1
Installing Windows
Set up following the
pre-install checklists in the
installation guide below.
For Linux: Chapter 1
Installing Linux
At the time of high
temperature, shutdown is
executed by
ESMPRO/ServerAgent
Service.