Summary of Contents for Bartec Lumen X4

  • Page 1 ATEX / IECEx Zone 2 and 22 CSA Class I Division 2 Lumen X4 User Manual 4,3" Industry Mobile Computer Type B7-A2P4-../..
  • Page 3 User Manual - Translation 4.3" Industry Mobile Computer - Lumen X4 Type B7-A2P4-…./…….. ATEX / IECEx Zone 2 / 22 CSA Class I Division 2 Document No.: B1-A2P4-7D0001 / 391871 Revision 0 / Status: 23 March 2016 Proviso: Subject to technical changes. Changes, mistakes and printing errors do not substantiate any claim to damages.
  • Page 4: Table Of Contents

    5.4.2 Insert battery ..............................26 5.4.3 Charge battery ..............................26 5.4.4 Turning On and Off the Lumen X4 Industry Mobile Computer ................ 27 5.4.5 Resetting the Lumen X4 to factory defaults ..................... 28 5.4.6 Remove/replace screen protector ........................29 RFID HF / NFC ..............................29 Subject to technical changes.
  • Page 5 4.3" Industry Mobile Computer - Lumen X4 Table of Content Type B7-A2P4-.…/…….. Operation ....................................30 Final inspection ..............................30 Care and cleaning ............................30 6.2.1 Care ................................. 30 6.2.2 Cleaning ................................30 6.2.3 Suitable materials for cleaning ......................... 31 Operation, recommendations and requirements ..................... 32 6.3.1...
  • Page 6 - empty -...
  • Page 7: Basic Safety Information

    The BARTEC company reserves the right to carry out technical changes at any time. In no event will BARTEC company be responsible or liable for indirect or consequential damages resulting from the use or application of this User Manual.
  • Page 8: Languages

    1.1.2 Changes in the document BARTEC reserves the right to change the content of this document without notification. No warranty is assumed for the correctness of the information. In cases of doubt, the German safety instructions apply because it is not possible to rule out errors of translation or printing.
  • Page 9: Unintended Use

    4.3" Industry Mobile Computer - Lumen X4 Basic Safety Information Type B7-A2P4-.…/…….. 1.3.2 Unintended use Any other use is unintended and may lead to damage and accidents. The manufacturer shall not be liable for any use extending beyond the exclusive purpose.
  • Page 10: Inspection

    4.3" Industry Mobile Computer - Lumen X4 Basic Safety Information Type B7-A2P4-.…/…….. 1.6.2 Inspection According to EN/IEC 60079-17 and EN/IEC 60079-19, the operator of electrical systems in potentially explosive atmospheres is obliged to have these inspected by an electrician to ensure correct condition.
  • Page 11: Co-Applicable Documents - Set Of Documents

    − Cases of disaster through the impact of foreign bodies and force majeure. The BARTEC company grants a warranty period of three years starting from the date of delivery from the Bad Mergentheim factory on the Industry Mobile Computers (exception: battery 6 months).
  • Page 12: Definition Of Terms

    4.3" Industry Mobile Computer - Lumen X4 Basic Safety Information Type B7-A2P4-.…/…….. 1.10 Definition of terms A few abbreviations are used in the documentation. Non Incendive => is used as generic term for Zone 2 and Division 2 version Lumen X stands for the entire explosion-protected product series 1.11...
  • Page 13: Product Description

    BARTEC for use in potentially explosive atmospheres. The Lumen X4 Industry Mobile Computer is based on the ARM Cortex-A7 Quad Core processor running at 1.5GHz. The 4.3-inch capacitive multi-touch display offers 480 x 800 pixel WVGA resolution.
  • Page 14 4.3" Industry Mobile Computer - Lumen X4 Product Description Type B7-A2P4-.…/…….. Position Designation Description Earpiece Use to listen during phone conversation Barcode Scan Barcode Scan Window Window (will change to black lens when without barcode) Webcam 2 MP to capture a front view picture and use for Video call Proximity &...
  • Page 15: Purpose Of Use

    (radio) transmission of data within potentially explosive atmospheres. The Lumen X4 Industry Mobile Computer is used exclusively in combination with devices which comply with the requirements placed on the overvoltage category I. The Lumen X4 Industry Mobile Computers, Type B7-A2P4-…./…….., have been...
  • Page 16: Technical Data

    4.3" Industry Mobile Computer - Lumen X4 Technical Data Type B7-A2P4-.…/…….. Technical data Explosion protection NI ATEX Zone 2 and 22 Type B7-A2P4-.…/…….. Lumen X4 Labelling II 3G Ex ic IIC T5 Gc II 3D Ex ic IIIB T100°C Dc IP54 -20 °C ≤...
  • Page 17: Applicable Standards

    4.3" Industry Mobile Computer - Lumen X4 Technical Data Type B7-A2P4-.…/…….. Applicable standards Explosion protection EN 60079-0:2012 Explosive atmospheres - Part 0: + A11:2013 Equipment - General requirements Explosive atmospheres - Part 11: EN 60079-11:2012 Equipment protection by intrinsic safety "i"...
  • Page 18: Features

    4.3" Industry Mobile Computer - Lumen X4 Technical Data Type B7-A2P4-.…/…….. Electromagnetic compatibility (EMC) Electromagnetic compatibility and radio spectrum matters EN 300 440-1 (ERM) – short range devices – radio equipment to be used in V1.6.1:2010 the 1 GHz to 40 GHz frequency range – Part 1: Technical...
  • Page 19: Physical Features

    4.3" Industry Mobile Computer - Lumen X4 Technical Data Type B7-A2P4-.…/…….. Software development Own development possible with standard Google Android SDK. Additional are the OS image, SDK and drivers available as download. 3.3.2 Physical features Dimensions in mm/in 132.7 x 82 x 25.7 mm Length x Width x Height (5.22 x 3.23 x 1.01 inch)
  • Page 20: Voice And Data Transmission Wi-Fi (Wireless Lan)

    4.3" Industry Mobile Computer - Lumen X4 Technical Data Type B7-A2P4-.…/…….. 3.3.4 Voice and data transmission Wi-Fi (Wireless LAN) Wi-Fi connections are realised with the assistance of ARM® Cortex™-A7 Quad Core 1.5 GHz processor. WLAN radio module IEEE 802.11a/b/g/n Radio standard Data rate IEEE802.11a:...
  • Page 21: Barcode Scan Options

    1D/2D Imager (SE4500 from Zebra) 3.3.8.1 1D/2D Imager (SE4500 from Zebra) For Lumen X4 with integrated 1D/2D Imager 1D-/2D-Imager Engine (omni directional) decodes/reads 1D- and 2D barcodes. The decoding range depends on the quality and size of the barcode and the software setting of the scan or engine.
  • Page 22: Decode Range

    4.3" Industry Mobile Computer - Lumen X4 Technical Data Type B7-A2P4-.…/…….. 3.3.10 Decode range 3.3.11 RFID The maximum read/write ranges of the RFID reader will depend on the different ambient conditions. For example: Transponder (tag), size Aerial used in the tag (size, model ...)
  • Page 23: Battery

    Do not open, disassemble, puncture, or crush the battery.  Do not leave or store the Lumen X4 Industry Mobile Computer in an area which is  near a heat source such as vehicle dashboard, dryer or other heat source.
  • Page 24: External Interfaces

    The external interfaces "Micro USB Type B (OTG Host, data exchange and  charging), Pogo Pin (charging in docking station)" may only be used outside the potentially explosive range with accessories specified by the manufacturer. Only use original BARTEC/Winmate accessories.  Product labelling Subject to technical changes.
  • Page 25 4.3" Industry Mobile Computer - Lumen X4 Technical Data Type B7-A2P4-.…/…….. Serial number Type plate Laser warning Only for devices with integrated 1D/2D Imager Warning IMEI number Only for devices with integrated 3.75G modules Type plate SIM card slot Micro card slot...
  • Page 26: Laser Labels

    4.3" Industry Mobile Computer - Lumen X4 Technical Data Type B7-A2P4-.…/…….. Laser labels The accessible laser radiation is in the visible spectral range (630nm to 680nm). It is not dangerous to the eye for short term exposure (up to 0.25 s).
  • Page 27: Transport And Storage

    Replace the battery if the operating time has shortened considerably. The standard warranty period for all BARTEC batteries is six months, whereby it is irrelevant whether the battery was acquired separately or was contained in the scope of the delivery of the Industry Mobile Computer.
  • Page 28: Commissioning

    DANGER Unintended use endangers explosion protection. Risk of fatal injury in an explosive atmosphere! Do not make any changes to the Lumen X4 Industry Mobile Computer.  In the case of functional disturbances or damage to the enclosure, the device ...
  • Page 29: Requirements In Potentially Explosive Atmosphere

    Only charge the battery (type B7-A2Z0-0034) outside the potentially explosive atmosphere. Only use the battery for the purpose listed in this User Manual. Is only suitable for the Lumen X4, Type B7-A2P4-…./…….. It is not allowed to remove, change and/or charge the battery inside the potentially explosive atmosphere.
  • Page 30: Handling Accessories

    − Only install or replace accessories outside the potentially explosive atmosphere. − User accessories exclusively which have been tested or certified by BARTEC for this purpose. − The end user can replace the SIM card, micro SD card, hand strap, and screen protector himself.
  • Page 31: Insert Sim Card And Micro Sd Card

    4.3" Industry Mobile Computer - Lumen X4 Commissioning Type B7-A2P4-.…/…….. 5.4.1 Insert SIM card and Micro SD card ATTENTION Damage to the SIM / micro SD card through electrostatic discharges! Use an antistatic mat.  Ensure that the operator is correctly earthed.
  • Page 32: Insert Battery

    4.3" Industry Mobile Computer - Lumen X4 Commissioning Type B7-A2P4-.…/…….. 5.4.2 Insert battery DANGER In potentially explosive atmospheres, battery latches must be locked. Danger to life exists! Check the locking of the battery latches carefully.  Work steps: Only charge, install or replace the battery outside the potentially explosive atmosphere.
  • Page 33: Turning On And Off The Lumen X4 Industry Mobile Computer

    2. The Industry Mobile Computer LED indicator indicates the status of the battery charging. 5.4.4 Turning On and Off the Lumen X4 Industry Mobile Computer Turning the device on Work steps: 1. Press and hold the Power On/Off button (g) for 3 seconds, located on the right side of the device.
  • Page 34: Resetting The Lumen X4 To Factory Defaults

    4.3" Industry Mobile Computer - Lumen X4 Commissioning Type B7-A2P4-.…/…….. 5.4.5 Resetting the Lumen X4 to factory defaults Work steps: 1. Tap MENU and then tap System settings. 2. Tap Backup & reset. 3. Tap Factory data reset. The user can select to back up application data, Wi-Fi passwords and other settings to Google servers by tapping Back up my data.
  • Page 35: Remove/Replace Screen Protector

    Do not use any sharp objects to remove the screen protector!  The screen protector can be ordered from BARTEC. The installation instructions for the screen protector forms part of the scope of delivery. Parts number: B7-A2Z0-0035 screen protector, 1 piece.
  • Page 36: Operation

     Is the battery correctly inserted and locked?  Does the screen protector (if used) have the requisite certification?  Is the micro SD card specified for the Industry Mobile Computer "Lumen X4"?  Has the SIM card been correctly inserted? ...
  • Page 37: Suitable Materials For Cleaning

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. ATTENTION Devices and accessories can be destroyed if handled incorrectly! Generally separate the charger from the power supply.  Only clean the interface contacts if the battery has been removed.
  • Page 38: Operation, Recommendations And Requirements

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Operation, recommendations and requirements 6.3.1 Basic safety and health protection requirements Consult your local health and safety officer to ensure that you are acquainted with the safety regulations in your company which serve to protect employees at the workplace.
  • Page 39 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Road traffic safety Do not take any notes and do not use the device when driving. Making a list of to-dos or browsing through the address book when driving has a negative effect on safe driving.
  • Page 40: Information On The Use Of Wireless Devices

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. The “Mobile Communication Industry” requests you to give safety priority when using your device/telephone. 6.3.2 Information on the use of wireless devices Heed all warnings referring to the use of wireless devices.
  • Page 41: Equipment Of The Laser Devices

    If you use LED for the camera flash, keep the camera flash LED at least 317 mm  (12.5 inch) away from a person’s eyes. Otherwise serious damage may be caused to the eyes. Devices from BARTEC/Winmate equipped with LED devices comply with the following guidelines: − IEC 62471:2006-07 for LED safety.
  • Page 42: Operating Frequency - Fcc And Ic

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Country-specific roaming This device has the International Roaming function (IEEE802.11d) which ensures that the device is used on the channels prescribed for the respective country. Ad-hoc operation The ad-hoc operation is restricted to the channels 36–48 (5150–5250 MHz). The use of this bandwidth is restricted to indoor areas;...
  • Page 43 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Connecting the device to a different socket than the one to which the receiver is connected. Advice from the dealer or a radio/television technician. Declaration in accordance with the FCC regulations, Part 15.21 Changes which have not been explicitly approved by the party responsible for compliance with the regulations can lead to the expiry of the operating authorization for this device.
  • Page 44: Electromagnetic Fields

    Portable devices have been specially tested for operation in direct body proximity. Use exclusively belt clips, holsters and similar accessories which have been tested and approved by BARTEC to ensure compliance with the FCC regulations. Belt clips, holsters and similar accessories of third manufacturers may not satisfy the FCC requirements for the recommended maximum values for electromagnetic fields and should not therefore be used.
  • Page 45: Use The Android 4.2 Operating System

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Use the Android 4.2 Operating System 6.6.1 Wake up the phone If you do not use the phone for a while, the screen dims and then darkens to conserve the battery.
  • Page 46: Use The Home Screen

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.6.3 Use the Home screen Home screen is the starting point to access all the features on the Industry Mobile Computer. It displays application icons, widgets, shortcuts, and other features. User can personalize the home screen.
  • Page 47 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 2. On the menu that opens tap the type of item you want to add. Move an item Work steps: 1. Tap and hold the item you want to move, until it can be moved.
  • Page 48 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 2. Drag the item you want to remove to the Remove icon. When the item (c) turns red, release yout finger. The element you want to remove is removed. View other parts of the Home Screen Extensions to the Home screen provide extra space for APPS, shortcuts, and other items.
  • Page 49 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Notification The following icons indicate that you have received notification. icons New email message Incoming call New text or multimedia Missed call message Alarm is set Speakerphone is activated Upcoming event...
  • Page 50: Use The On-Screen Keyboard

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.6.5 Use the On-Screen Keyboard The user will be able to enter text using the On-Screen Keyboard. Some applications will launch the keyboard automatically. In others, the user needs to touch a text field where the user wants to enter text to launch the keyboard.
  • Page 51: Edit Text

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.6.6 Edit text Select text Work steps: 1. Double Tap the text you want to select. 2. Tap to select all the sentences in the menu that appear. The selected text is highlighted in blue, with a tab at each end of the selected word.
  • Page 52: Set The Display

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.6.7 Set the display Use the display settings to configure brightness and other screen settings. Work steps: 1. Tap MENU and then tap System settings. 2. Tap Display. In the DEVICE part, the following options will be offered:...
  • Page 53: Set Language And Keyboard

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.6.10 Set language and keyboard Use the language & keyboard settings to select the language for the text on your Industry Mobile Computer and for configuring the On-Screen Keyboard, including words that you have added to its dictionary.
  • Page 54: Usb Debugging Setting

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.6.11 USB debugging setting To permit debugging tools on a computer to communicate with the user’s Industry Mobile Computer via USB connection. Work steps 1. Tap MENU and then tap System settings.
  • Page 55: Messaging

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Make a phone call using the contact list Work steps: 1. Tap the Launcher and then tap Contacts or tap the phone icon at the bottom of the home screen and then tap Contacts 2.
  • Page 56: About The Phone

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.6.14 About the phone About Phone includes information about user’s Industry Mobile Computer. Provides information regarding the local or online System Update update of your devices. Opens the status screen with a list of information...
  • Page 57: Turn On The Data Service

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Do not change the parameters of the access point to prevent the user to be unable to access network sources. 6.7.2 Turn on the data service Work steps: 1. Tap MENU and then tap System settings.
  • Page 58: Connection To Bluetooth Devices

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Add a Wi-Fi Network Work steps: 1. Turn on Wi-Fi, in the Wi-Fi settings screen, tap on the + icon (d). 2. Input the SSID (name) of the network (e), if the network is secured, tap the security menu and then tap the type of security (f) deployed on the network.
  • Page 59: Connection / Disconnection Via Usb

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Connection / disconnection via USB DANGER Non certified accessories endanger explosion protection. Danger to life exists in potentially explosive atmospheres! The external Micro USB Type B interface (OTG Host, data exchange, and ...
  • Page 60 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. When the device is connected as USB storage, the screen indicates that USB storage is in use and user will receive a notification. Disconnect Lumen X4 Work steps: 1. Tap the notification panel and then tap USB connected.
  • Page 61: Use The Camera

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.10 Use the camera The Industry Mobile Computer is equipped with a 8 MP camera on the rear side and a 2 MP camera on the front side, which the user can use to capture photos or video.
  • Page 62: Record A Video

    4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. Share photo Delete photo View another photo or video in the gallery. Swipe right or left to view more photos. 6.10.3 Record a video Work steps: 1. Tap the Record icon to start the video recording.
  • Page 63: Daten Mit Punkt Zu Punkt (P2P) Verbindung Übertragen

    1. There are two NFC capable devices required. 2. Enable NFC on the receiver device. 3. Enable NFC function on Lumen X4 as described in chapter 6.11.1. 4. Select the program or file what you transmit. 5. Bring both NFC devices close together that connection can established.
  • Page 64: Use Read / Write Function

    RFID HF/NFC reader. Another option is to use the standard Google Android SDK (Software Development Kit) for development of a customized solution. For the Lumen X4 is a SDK available for download what is needed for the development. Example Application for test: Open Google App Store and search for “NXP”...
  • Page 65: 2D Imager

    The Lumen X4 is optionally available with a Zebra 1D/2D imager. Zebra Type: SE4500-SR A software tool has been preinstalled on the Lumen X4 for test purposes and simple applications. The “WDC – Data Capture” tool permits a customised configuration of the scanner.
  • Page 66 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.12.2.2 Switching the scanner on/off 1. WDC – Data Capture start screen Select “Barcode Settings”. The scanner is switched on automatically when the WDC – Data Capture Tool is started.
  • Page 67 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.12.2.4 Setting the prefix / suffix 1. WDC – Data Capture start screen Select “Prefix / Suffix”. 2. Which characters or commands are to be used as prefix / suffix can be set in the menu.
  • Page 68 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.12.2.6 Setting triggers 1. WDC – Data Capture start screen Select “Trigger Settings”. 2. The trigger settings can be configured in the menu. Auto Scan – barcode reader starts automatically when the user exits the WDC application.
  • Page 69 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.12.2.7 Displaying the activated barcode symbols 1. WDC – Data Capture start screen Select “Code Types About”. 2. The activated barcode symbols are displayed in the menu. WDC – Data Capture - Barcode Settings –...
  • Page 70 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.12.2.9 Resetting the application 1. WDC – Data Capture start screen Select “Reset Settings”. 2. WDC – Data Capture Tool is reset to default settings. WDC – Data Capture - Start Screen 6.12.2.10...
  • Page 71 4.3" Industry Mobile Computer - Lumen X4 Operation Type B7-A2P4-.…/…….. 6.12.2.11 Barcode scanning 1. Exit the WDC – Data Capture application. 2. In the default setting, the barcode scanner functions as a keypad. As a result, the barcode data can be read into every active box in any application.
  • Page 72: Faults And Troubleshouting

    When using external audio devices check whether the cable loudspeaker. has been connected correctly. No laser appears with the 1D/2D Check that a Lumen X4 with integrated 1D/2D Imager is used. imager and it does not appear to Check in the settings whether the scanner is enabled. work.
  • Page 73: Service, Inspection, Repair

    Repair Service, Inspection, Repair Service, inspection, and repair of Lumen X4 Industry Mobile Computers may be conducted exclusively by trained and qualified staff! The staff who is familiar with the service, inspection, and repair of Lumen X4 Industry Mobile Computers, has been informed about the risks and has the qualifications necessary for this work.
  • Page 74: Disposal

    Repair, Disposal, 4.3" Industry Mobile Computer - Lumen X4 Packaging Type B7-A2P4-.…/…….. Please read through the handling guidelines for the RMA process before you send in a defective device for repair. Then complete the RMA form (Return Merchandise Authorization), sign it and send it to our "Returns Centre".
  • Page 75: Accessories

    - AC line cord (US) - 3 wired 03-9609-0021 Vehicle Docking Station Input voltage: DC 9 V up to 36 V, Charging of the Lumen X4 03-9914-0020 Dimension: 86.7 x 38.5 x 162.5 mm Interfaces: 1 x Terminal block for connection to cigarette lighter...
  • Page 76: Additional Information

    Additional Information Type B7-A2P4-.…/…….. Additional Information 12.1 Links All original Winmate documents refer to the non-explosion-protected version. Please heed the safety information in the BARTEC manuals when using original Winmate documents. http://www.bartec-group.com BARTEC website http://www.bartec.de/automation-download/ BARTEC download page Subject to technical changes.
  • Page 78 Your partner for safety technology. Challenge us! BARTEC GmbH Max-Eyth-Str. 16 Phone: +49 7931 597-0 info@bartec.de Germany 97980 Bad Mergentheim Fax: +49 7931 597-119 www.bartec.de...