ELECTRICAL REQUIREMENTS

Before you insert the plug into the wall socket make sure that the voltage and the
frequency shown in the rating plate inside the appliance corresponds to your
electricity supply.
Rating label is on the left hand side of fridge inner liner.
We recommend that this appliance be connected to the mains supply via a
suitable switched and fused socket. The appliance must be positioned so that
the plug is accessible.
Should the mains lead of the appliance become damaged or should it need
replacing at any time, it must be replaced by a special purpose made mains lead
which can only be obtained from a BEKO Authorised Service Agent.
WARNING! THIS APPLIANCE MUST BE EARTHED
If the fitted moulded plug is not suitable for your socket, then the plug should be
cut off and an appropriate plug fitted. Destroy the old plug which is cut off as a
plug with bared cord could cause a shock hazard if inserted into a socket
elsewhere in the house.
The moulded plug on this appliance incorporates a 13 A fuse. Should the fuse
need to be replaced an ASTABEAB approved BS 1362 fuse of the same rating must
be used. Do not forget to refit the fuse cover. In the event of losing the fuse cover
the plug must not be used until a replacement fuse cover has been fitted. Colour
of the replacement fuse cover must be the same colour as that visible on the pin
face of the plug. Fuse covers are available from any good electrical store.
IMPORTANT! FITTING A DIFFERENT PLUG
As the colours of the wires in the
mains lead of this appliance may
not correspond with the coloured
markings identifying the terminals
in your plug proceed as follows:
(See diagram).
1. Connect the green-yellow or
green (Earth) wire to the terminal
in the plug marked 'E' or with
the symbol
or coloured
green and yellow or green.
2. Connect the blue (Neutral) wire
to the terminal in the plug
marked 'N' or coloured black.
3. Connect the brown (Live) wire to
the terminal in the plug marked 'L'
or coloured red.
With alternative plugs a 13 A fuse must be fitted either in the plug or adaptor or
in the main fuse box.
If in doubt contact a qualified electrician.
GREEN &
6mm.
YELLOW
OR
L
GREEN
BROWN
OR
N
RED
22mm.
BLUE
OR
BLACK
CORD GRIP