Input Characteristics
•
Max switch impedance 1.0 kOhm
•
Input Isolation between Input 1 to Input 2 = 20 kOhm
Local Configuration
•
Integrated LCD display with membrane switch buttons
•
Display cycles through Input 1, Input 2 and error messages, if
applicable
•
Configure RF parameters locally using membrane switch
buttons
Power Characteristics
•
Self-contained power
•
'C' Size 3.6 V lithium battery
•
Up to five year battery life (depends on sample rate and RF
update rate), field replaceable
Self-Diagnostics
•
Low battery alarm– indicates the need to replace the battery
(approximately one month warning)
•
Contains extensive self-checking software and hardware that
continuously monitors the operation. Any device parameter out
of spec is identified and reported.
Intrinsic Safety Entity Parameters
•
V
= 30 VDC
Max
•
I
100 mA
Max =
•
P
900 mW
Max =
•
Maximum operating temperature = 85 °C
•
Temperature Class T4