CAUTION WHEN SERVICING
1. Disassembly instructions
1) Remove the COVER, TOP and COVER, BOTTOM.
2) Remove the DFP.
3) Remove the four screws (indicated by the arrows) from the
CD mechanism. (Fig. 1)
Screw (a) x 2: VTT2.6-6
Screw (b) x 2: VTT2.6-3B
2. Servicing position
Put the DFP onto the CD CASE to fix it. (Fig. 2)
– 4 –
Fig. 1
Fig. 2