Page 2
Programming Instructions Programming can be accomplished manually using the machine controls or by connecting to the machine control using a PDA (personal digital assistant). For instructions on using a PDA with this washer control, please contact your local Dexter distributor. Please read below for manual programming instructions.
Page 3
#4 Warm Water Price: The next step in the pricing program is to set the additional price for Warm water usage. The display will blink fi rst “CH P” indicating cold/hot water mix price and then “00.00”. To change the value, use the Hot temperature button to decrease and the Warm temperature button to increase.
Page 4
To change the washer cycle, push the Hot temperature button once. The display will change to “C 1”, indicating cycle one is selected. The temperature buttons are used to make changes to the program. In the program mode, these buttons will do as displayed in drawing below. When the display shows “C 1”, push Enter.
Page 5
Coin Washer Cycle Parameter Ranges The range of each cycle parameter is shown below: Bath Cycle Time “ct” 0 to 15 minutes for Prewash, Rinse1 and Rinse 3 to 15 minutes for Wash and Final Rinse. For the baths that can, if the time is set to zero, then that bath will be eliminated from the cycle.
Coin Washer Default Cycle (Preset at Factory) The following table shows the complete details for the coin washer default cycle. Bath Bath Cycle Time (min.) Water Temp. Water Level* Delay Fill Spin Time (min.) IS * Prewash Wash Rinse 1 Rinse 2 Final Rinse *NOTE:...