Download Print this page

Part Vi: The Main Parts Parameters And Troubleshooting - Whirlpool WDC 1070SL Service Manual

10kg capacity
Hide thumbs

Advertisement

Part VI: The Main Parts Parameters and Troubleshooting

6.1 Three-Way Valve
Specifications:
Part Number:
Rated voltage:
rated power:
Resistance (at 20 degrees):
Flow rate:
Installation:
Symptom
1.There is no water
2.The water filling stopped
3. Water Leak
W10448090
220V +10%/-25%, 50/60Hz
6W
1140 Ohm+/-10%
8 ±5% L/min (from 1.5 to 5 bar)
Snap On
Description
Open Coil
Tap Is Not Turned On
Clogged Inlet Valve Filter
Loose Connector
Defective Inlet Valve
Defective Inlet Valve
Check
Check coil resistance
Check faucet
Clean the filter
Check if connectors are properly
seated
Replace Inlet Valve
Replace Inlet Valve

Advertisement

loading