Epson Trume TR-MB7 User Manual page 138

Table of Contents

Advertisement

MB73 (TR-MB7)
User's Guide
Barometric pressure measurements
Trouble
Cannot measure
The measurement results of
barometric tendency do not
seem correct
The small second hand does
not stop
Troubleshooting
If the indicator hand is pointing to E, there is not enough battery power
remaining to perform measurements.
Charge the watch until the remaining battery level is 2 or higher.
"Charging the watch" on page 41
U
If the indicator hand is pointing to
Release In-flight mode on the watch.
"Setting In-flight Mode" on page 36
U
If the small second hand points to - (failure) after pressing and releasing
the C button, an error may have occurred in the pressure sensor.
If this continues to occur, contact your local dealer or TRUME customer
support.
"Contact Information" on page 152
U
Barometric tendency is calculated based on the measurement results of
atmospheric pressure over the last three hours (automatically
measured approximately every 10 minutes). Depending on the
automatic measurement timing, barometric tendency may not be
calculated correctly.
"Notes and Mechanism on Measuring Barometric Pressure" on
U
page 107
When an altitude difference occurs due to movements to different
heights, barometric tendency may not be calculated correctly.
"Notes and Mechanism on Measuring Barometric Pressure" on
U
page 107
If the barometric tendency rises or falls, the small second hand vibrates
back and forth.
138
Causes and Solutions
, the watch is set to In-flight mode.

Advertisement

Table of Contents

Troubleshooting

loading