Structure Of The Heater; Operating Conditions; 4.1. General - Drazice OKHE 100 Operation And Installation Manual

Tank-type water heaters for vertical mounting
Table of Contents

Advertisement

To limit regulation - pull off the thermostat knob (it will be tough at first) and you will find two cylindrical pins
Ø2,15mm on the back side of the knob
- pull off one pin and insert it to the corresponding hole of the selected maximum temperature.
- put the knob back on (to the stop).
To block the setting – set the selected temperature
pull off the thermostat knob without changing the setting, there are two pins on the back
side of the knob
Pull off both of them and fit them to the holes corresponding with the selected
temperature so that the gap between the pins was without a hole, and the position was
opposite the set temperature.
3.

Structure of the heater

1
thermometer
2
heating element well
3
ceramic heating element
4
operation thermostat with external control
and safety thermostat
5
electric installation guard
6
cold water filling pipe
TAB. 2
service weight
4.

Operating conditions

4.1. General

The tank shall only be used in accordance with the conditions specified on the performance plate and in instructions
for electric wiring. Besides legally acknowledged national regulations and standards, also conditions for connection
defined in local electric and water works have to be adhered to, as well as the installation and operation manual.
Regulation limited
2000W
Type
OKHE 80
A
742
B
610 (560)
C
127 (177)
37 kg
To block the setting
7
thermowell
8
hot water withdrawal pipe
9
Mg anode
10
enamelled steel receptacle
11
polyurethane insulation
12
heater shell
OKHE 100
OKHE 125
887
1052
700 (650)
850 (800)
182 (232)
197 (247)
42 kg
49 kg
4
OKHE 160
1237
1050 (1000)
182 (232)
57 kg

Advertisement

Table of Contents
loading

This manual is also suitable for:

Okhe 160Okhe 80Okhe 125

Table of Contents