Section 6: Wire Resistance Table - Emerson SC311 Reference Manual

Infrared combustible gas sensor
Hide thumbs Also See for SC311:
Table of Contents

Advertisement

Wire resistance table
June 2016

Section 6: Wire resistance table

Distance
Feet (meters)
100 (30.5)
200 (61)
300 (91.4)
400 (121.9)
500 (152.4)
600 (182.9)
700 (213.4)
800 (243.8)
900 (274.3)
1000 (304.8)
1250 (381)
1500 (457.2)
1750 (533.4)
2000 (609.6)
2250 (685.8)
2500 (762)
3000 (914.4)
3500 (1066.8)
4000 (1219.2)
4500 (1371.6)
5000 (1524)
5500 (1676.4)
6000 (1828.8)
6500 (1981.2)
7000 (2133.6)
7500 (2286)
8000 (2438.4)
9000 (2743.2)
10000 (3048)
Resistance shown is one way. This figure must be doubled when determining closed loop resistance.
18
20 AWG
18 AWG
0.5 mm
2
0.8 mm
2
(ohms)
(ohms)
1.02
0.64
2.03
1.28
3.05
1.92
4.06
2.55
5.08
3.20
6.09
3.83
7.11
4.47
8.12
5.11
9.14
5.75
10.20
6.39
12.70
7.99
15.20
9.58
17.80
11.20
20.30
12.80
22.80
14.40
25.40
16.00
30.50
19.20
35.50
22.40
40.60
25.50
45.70
28.70
50.10
32.00
55.80
35.10
61.00
38.30
66.00
41.50
71.10
44.70
76.10
47.90
81.20
51.10
91.40
57.50
102.00
63.90
16 AWG
14 AWG
1.0 mm
2
2.0 mm
2
(ohms)
(ohms)
0.40
0.25
0.80
0.51
1.20
0.76
1.61
1.01
2.01
1.26
2.41
1.52
2.81
1.77
3.21
2.02
3.61
2.27
4.02
2.53
5.03
3.16
6.02
3.79
7.03
4.42
8.03
5.05
9.03
5.68
10.00
6.31
12.00
7.58
14.10
8.84
16.10
10.00
18.10
11.40
20.10
12.60
22.10
13.91
24.10
15.20
26.10
16.40
28.10
17.70
30.10
19.00
23.10
20.20
36.10
22.70
40.20
25.30
Reference Manual
MAN-0091, Revision 8
Wire resistance table

Advertisement

Table of Contents
loading

Table of Contents