Wps Suggestion For Weld Identifiers; Tig Drop-Down Filtering; Smart Reader Usage And Wps Limit Enforcement - Kemppi Smart Reader Operating Manual

Table of Contents

Advertisement

WELDEYE
selection or MiniLog's state changes. The correct WPS is always applied during the welding based
on the predefined mappings.

5.4 WPS suggestion for weld identifiers

In the WeldEye cloud service, it is possible to assign one or more WPSes for a weld identifier.
When the weld barcode is scanned with Smart Reader, Smart Reader can automatically select the
correct WPS, or display a selection list of WPSes.
This feature is controlled in the WeldEye cloud service settings.

5.5 TIG drop-down filtering

To reduce the number of unnecessary warnings on the Smart Reader display, Smart Reader
applies TIG drop-down filtering.
When welding long runs with TIG, it is not ideal to stop the arc. However, the welder may need to
change the filler wire during welding while keeping the welding bead melting. During this time,
the welding current can be dropped to low levels to keep the arc on, but not burning through the
base material.
This feature is controlled in the WeldEye cloud service settings.

5.6 Smart Reader usage and WPS limit enforcement

Kemppi FastMig X welding machine supports enhanced integration with Smart Reader, enabling
Smart Reader usage enforcement and WPS limit enforcement.
For more information about this feature or how to enable it, contact WeldEye support. See
Contact information
Smart Reader usage enforcement
In some cases, it is desirable to enforce the use of Smart Reader to ensure that all welding
parameters are collected. For these occasions, it is possible to adjust FastMig X welding machine
so that it cannot be used for welding if Smart Reader is not connected and welder identification
scanned. Furthermore, it is possible to require the welder to give the WPS identification before
the welding machine is functional.
WPS limits enforcement
Smart Reader can adjust the welding machine automatically according to the parameter values
defined in the WPS, and enforce the WPS limits so that they cannot be exceeded by adjustments
through the welding machine panel. Smart Reader can automatically adjust the following welding
parameters: current, voltage, wire feed speed, and the welding program.
OPERATING MANUAL | EN
on page 37.
31
5.4 WPS suggestion for weld identifiers
©
KEMPPI | 2017-12-22

Advertisement