Download Print this page
Frico PA3200C Assembly And Operating Instructions Manual

Frico PA3200C Assembly And Operating Instructions Manual

Air curtain

Advertisement

Quick Links

SE
.... 16
FR
.... 50
GB
.... 23
IT
.... 57
NO
.... 29
NL
.... 64
Original instructions
PA3200C
DE
.... 36
PL
.... 71
ES
.... 43
RU
.... 78

Advertisement

loading

Summary of Contents for Frico PA3200C

  • Page 1 Original instructions PA3200C ..16 ..23 ..29 ..36 ..43 ..50 ..57 ..64 ..71 ..78...
  • Page 2 PA3200C Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
  • Page 3 PA3200C DN20 (3/4") 1045 / 1555 / 2045 outside thread 1045 / 1555 / 2045 1045 / 1555 / 2045 1068 / 1578 / 2068 min 500 1068 / 1578 / 2068 1068 / 1578 / 2068 min 500 min 500 DN20 (3/4 ")
  • Page 4 PA3200C Gland Gland ø17,5 ø17,5 Knock-out ø32,5 Knock-out ø25,5 Gland ø20,5 Knock-out ø17,5 Fig. 2 Fig. 3: Open the unit.
  • Page 5 PA3200C Minimum distance Fig. 4 30 mm 60 mm Fig. 5...
  • Page 6 PA3200C Mounting with wall brackets Ø8 (3x) Ø7 Ø16 PA3210C 2 pcs 2 pcs PA3215C PA3220C 3 pcs Fig. 6: Mounting with wall brackets...
  • Page 7 PA2P15 PA3220C, 1 m PA2P20 PA3PF15 PA3210C, PA3215C PA3PF20 PA3220C PAMLK PA3200C PA3EF10 PA3210C W PA3EF15 PA3215C W PA3EF20 PA3220C W FHDN20 PA3200C W PA34TR PA2P PA3PF PA3EF PAMLK FHDN20 PA2DR PA2DR VLSP VOT15 DN15 DN20 VOT20 VOT25 DN25 VKF15LF...
  • Page 8 PA3200C PA3210CA / PA3215CA / PA3220CA 0 -10V N H1H2 N F1 F2 F3 Black Blue Black Brown Blue Black Blue Black Brown Blue...
  • Page 9 PA3200C PA3210CE8 / PA3215CE12 / PA3220CE16 0 -10V N H1H2 N F1 F2 F3 Yellow White Orange Black Blue Black Brown Blue Yellow White Orange Black Blue Black Brown Blue...
  • Page 10 PA3200C PA3210CE08YD / PA3215CE12YD / PA3220CE16YD 230V3~ 0 -10V N H1H2 N F1 F2 F3 Yellow White Orange Black Blue Black Brown Blue Yellow White Orange Black Blue Black Brown Blue...
  • Page 11 PA3200C PA3210CE08YD / PA3215CE12YD / PA3220CE16YD 400V3~ 0 -10V N H1H2 N F1 F2 F3 Yellow White Orange Black Blue Black Brown Blue Yellow White Orange Black Blue...
  • Page 12 PA3200C PA3210CW / PA3215CW / PA3220CW 0 -10V N H1H2 N F1 F2 F3 Black Blue Black Brown Blue Black Blue Black Brown Blue...
  • Page 13 PA3200C PAMLK 0 -10V N H1H2 N F1 F2 F3 N F1 F2 F3 Black Brown Blue Black Brown Blue...
  • Page 14 PA3200C Ambient, no heat - PA3200C A (IP21) Type Output Airflow* Sound Sound Voltage Amperage Length Weight power* pressure* motor motor [kW] [dB(A)] [dB(A)] [mm] [kg] PA3210CA 1100/1750 46/57 230V~ 1068 PA3215CA 1700/2750 46/59 230V~ 1578 PA3220CA 2300/3500 50/60 230V~...
  • Page 15 PA3200C Output charts water PA3200C Supply water temperature:80 °C Water temperature: 80/60 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water temp.
  • Page 16 Mounting with wall brackets (fig. 6) Application 1. Mount the brackets on the wall, see fig.6A PA3200C is a compact air curtain with a and dimension drawing fig.1. If the wall is recommended installation height of 3,2 uneven the brackets must be compensated metres.
  • Page 17 Note that the unit shall be preceded by a 2. The front hatch is removed by removing regulating valve, see Frico valve kit. the screws on the top of the unit and then The water coil is connected on top of the unit detach the bent edge at the bottom.
  • Page 18: Maintenance

    PA3200C Maintenance Temperature control Unit with water heating See control pages. The appliance filter should be cleaned regularly to ensure the air curtain effect and Replacing motor or impeller the heat emission from the device. How often 1. Remove the front.
  • Page 19 PA3200C Trouble shooting Safety If the fans are not working or do not blow properly, • For all installations of electrically heated check the following: products should a residual current circuit • The functions and settings of the built-in breaker 300 mA for fire protection be used.
  • Page 20 PA3200C Control The air curtain has an integrated control system and can be remotely controlled. 230V~ Actuator SD230 Black (remove the quick Brown connector) Blue PA2DR (accessory) External on/off Eg time switch. External potential free closure = off Factory setting dip-switches - Unit without heating...
  • Page 21: Functional Test

    PA3200C Fan step 1/2/3 ~20 °C Heat step Electric: Half/full power Water: On/off (1 LED) On/off Control panel - Unit with electrical heating or water heating Fan step 1/2/3 On/off Control panel - Unit without heating Remote control - on/off, fan steps and heating steps...
  • Page 22 Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...