SIGLENT SDM3065X Quick Strat
Hide thumbs Also See for SDM3065X:

Advertisement

Quick Strat
SDM3065X Digital Multimeter
QS06036-E01A
2017 SIGLENT TECHNOLOGIES CO.,LTD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDM3065X and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGLENT SDM3065X

  • Page 1 Quick Strat SDM3065X Digital Multimeter QS06036-E01A 2017 SIGLENT TECHNOLOGIES CO.,LTD...
  • Page 3 ● SIGLENT TECHNOLOGIES CO., LTD. All rights reserved. ● The information provided in this manual replaces all information printed before. ● SIGLENT Company has the rights to change the specification and the price. ● Contents in this manual are not allowed to be copied, extracted and translated without permission by the company.
  • Page 4: General Safety Summary

    Do not operate with suspected failures If you suspect that the product is damaged, please contact SIGLENT’s qualified service personnel to inspect it. Any repair and adjustment to the product or replacing a component should be done by qualified personnel only.
  • Page 5 Keep the surface of the instrument clean and dry. Do not operate in wet or damp conditions. Do not operate in flammable or explosive environment. The disturbance test of all the models meets the limit values SDM3065X Quick Start III...
  • Page 6  LOSense-LOSense protection limitation: 2Vpk. 3. Current input (I) terminal I and LO terminals are used for current measurement. The maximum current which go through the I terminal is limited to 10A by the fuse on the back panel. IV SDM3065X Quick Start...
  • Page 7 SDM3065X is capable of making measurements with the HI and LO inputs connected to mains in such devices (up to 600VAC) or the branch outlet itself. However, the HI and LO terminals of SDM3065X can’t be connected to mains in permanently installed...
  • Page 8 Voltages above 600VAC only can be measured in circuits that are isolated from mains. However, there may be transient overvoltage in circuits that are isolated from mains. SDM3065X is able to withstand occasional transient overvoltage up to 4000Vpk. Please don’t use this instrument to measure circuits that transient...
  • Page 9: Safety Terms And Symbols

    CAUTION indicates that a potential damage to the instrument or other property might occur. Symbols used on the instrument. Symbols may appear on the instrument: Hazardous Protective Warning Test Chassis Voltage Earth Ground Ground Ground SDM3065X Quick Start VII...
  • Page 10: Daily Maintenance And Cleaning

     To prevent the surface of the instrument or test leads from damages, please don’t use any corrosive or chemical cleaning reagents. Please make sure the instrument is already dry before restarting it to avoid short circuits or personal injuries caused by water. VIII SDM3065X Quick Start...
  • Page 11: Table Of Contents

    Front Panel ..................4 Rear Panel ..................7 Start the Multimeter ..............10 User Interface ................11 Measurement Connections ............12 To Use the Built-in Help System ..........15 Troubleshooting ................16 Contact SIGLENT ................ 17 SDM3065X Quick Start IX...
  • Page 12: General Inspection

    The consigner or carrier shall be liable for the damage to instrument resulting from shipment. SIGLENT would not be responsible for free maintenance/rework or replacement of the unit. 2. Inspect the instrument.
  • Page 13: Appearance And Size

    SIGLENT Appearance and Size 345.45mm 260 .27mm Appearance and Size SDM3065X Quick Start 2...
  • Page 14: To Adjust The Handle

    SIGLENT To adjust the Handle Please grip the handle by the two sides and pull it outward to adjust the handle position of SDM3065X. Then rotate the handle to the appropriate position. Please operate as the following figure: Handle Adjustment...
  • Page 15: Front Panel

    480*272 high resolutions that can the current function menus, measurement parameter settings, system status, prompt messages and so on. Menu Operation Keys Press any softkey to activate the corresponding menu. Measurement and Assistant Function Keys SDM3065X Quick Start 4...
  • Page 16 Return to local control of the instrument (when in Remote mode). Some of the front panel keys have text above them. This indicates that the key has a function that you can access by pressing and releasing [Shift] before pressing the key. 5 SDM3065X Quick Start...
  • Page 17 Move the cursor Apply the current setting Signal Input Terminals The measured signal (device) will be connected into the multimeter through these terminals. Different measurement objects have different connection methods. For details, please refer to “Measurement Connections”. SDM3065X Quick Start 6...
  • Page 18: Rear Panel

    (in the direction of the dotted arrow in the figure below) and pull out of the fuse seat. 3) Select a proper voltage scale. 4) Replace a specified fuse. 5) Reinstall the fuse seat into the slot. 7 SDM3065X Quick Start...
  • Page 19 USB Device Connect the PC through this interface. You can use SCPI commands or PC software to control SDM3065X remotely. Through this interface, the multimeter can be connected to the network for remote control. VMC Output...
  • Page 20 3) Place a new specified fuse. 4) Reinstall the fuse seat into the slot. Instrument Lockhole You can use the safety lock to lock the multimeter in a fixed place if necessary. 9 SDM3065X Quick Start...
  • Page 21: Start The Multimeter

    1. Make sure the power cord is in good connection. 2. Try to restart the multimeter, if it fails, check the power fuse and replace a new one when necessary. 3. If the problem still remains, please contact SIGLENT. SDM3065X Quick Start 10...
  • Page 22: User Interface

    SIGLENT User Interface Trigger Mode LAN Status Icon Trigger Mode Measuremet Function Measuremet Result Range Operation Menu User Interface 11 SDM3065X Quick Start...
  • Page 23: Measurement Connections

    SIGLENT Measurement Connections SDM3065X is designed with many measurement functions. After selecting the desired measurement function, please connect the signal (device) under test to the multimeter according to the method below. Do not discretionarily switch the measurement function when measuring as it may cause damage to the multimeter.
  • Page 24 SIGLENT Resistance Measurement (2-wire) Resistance Measurement (2-wire) Capacitance Measurement Frequency/Period Measurement Continuity Measurement Diode Measurement 13 SDM3065X Quick Start...
  • Page 25 SIGLENT Temperature Measurement (For RTD and thermcouple sensors) SDM3065X Quick Start 14...
  • Page 26: To Use The Built-In Help System

    The common help information is listed as the following: 1. Basic Measure. 2. Measuring Temperature. 3. Measuring Capacitance. 4. Math Function. 5. Dual-display Function. 6. Saving and Recalling Information. 7. Optional Multiple Scan Card. 8. The convention and Tips of Softkeys. 9. Technical Support. 15 SDM3065X Quick Start...
  • Page 27: Troubleshooting

    When you encounter those problems, please solve them following the corresponding steps. If the problem remains still, please contact SIGLENT and provide your device information. 1. If the screen is still dark with nothing displayed after pressing the power key.
  • Page 28: Contact Siglent

    USB storage device is no larger than 8G bytes. 4) Restart the instrument and then insert the USB storage device. 5) If the problem persists, please contact SIGLENT. Contact SIGLENT SIGLENT TECHNOLOGIES CO.,LTD Address: 3/F, building NO.4, Antongda Industrial Zone, 3rd Liuxian Road, Bao’an District, Shenzhen, P.R.China...