Operation - Kenmore 303.147012 Owner's Manual

17 gallon central humidifier
Table of Contents

Advertisement

WIRING TOCONSTANT
120 VAC UNE
EXTERNAL TOFURNACE
Junction _
_U
J
Inllal
SiI# _ddl
In Rltum
Air Plenum
Ill I
(_ _-._lly _
o=_s)
IIII
Pu_
this acce_loty separately
ifneeded.
IIII
Av=_ _o_ s_-s P,_,_ Ser_=
[] 6
Usinglowvoltagewire supplied,connectspadeter-
I
minalsto solenoidvalve on top of humidifier.
J
NOTE: Wiring mustconformto localcodes.
I
[] 7
Position and support wire to humidistat location.
Separate wire. Cut only one wire, strip ends.
[]
8
Feed wires thru opening in humidistatback plate
and attachto screwterminals.Mounthumidistaton retumair ple-
num using (4) #8 screwsprovided.Install shaftextension,cover
and knob (Fig. 16).
CONTROL CIRCUIT: Forproper operationand water conserve-
fion, this humidifiermustbe wiredso it willoperateonlywhen the
furnace blower is runningand the humidistatcalls for additional
humidity. T wo methodsare shown(Fig. 17 and Fig. 18):
Fig 17: WIRING INTO FURNACE - FOR ANY FORCED AIR
FURNACE WITH SINGLE SPEED 120 VAC BLOWER ONLY.
CAUTION: Do not use this methodwith multi-speedblow-
em or blowem otherthan 120 VAC.
Rg 18: WIRING EXTERNAL TO FURNACE- FOR ANY FORCED
AIR FURNACE INCLUDING FURNACE WITH OTHER THAN 120
VAC BLOWER MOTOR OR FURNACE WITH MULTI-SPEED
BLOWER MOTOR.
NOTE: Some furnacesare equippedwith accessorytermi-
nalsthat can be usedfor the humidifier. I n this case, consult
the fumane manufacturer'srecommendation for wiring.
[] 12
Attach"OperatingInstruction Laber to returnair ple-
num nexttothe humidistat. P eel offpaper backingand sticklabel
in desired location.
operation
[] 1
Set knobto the lowest temperaturepredictedfor a
24 hourpe_nd. Because ofdifferencesin houseconstruction you
may wanttotrya higheror lowersettingtoachieveproperhumidity.
[] 2
Change knob settings as outdoor temperature
changesoccur.
[
WARNING: DO NOT LEAVE KNOB SET IN "TEST" POSI-
TION ABOVE %20" OR HUMIDIFIER WILL RUN CON-
STANTLY.
I
IF SWEATING OF WINDOWS OR WALLS OCCURS OR IF AIR
IS TOO DRY:
Check dial seffing. Indicatorshould point to the lowest24 hour
temperature. If settingdoes not agree, readjust knobto proper
i
numberand wait 24 hoursfor sweatingto stop. Ifdial settingwas
correctand conditions have not changed, rotate knob beck and
forthfromTEST to MINIMUM HUMIDITY SETTING. If humidifier
goes ON and OFF, control is operatingproperly.
[] 9
Tum offelectricity at fusebox. Using(two)wire nuts
and conduit nut supplied, install24 VAC transformerto 120 VAC
supplyjunction box followingthe control circuitselected so the
transformer will be powered onlywhen the fumaceblower is run-
ning. Do not use existingtransformer on fumace.
8
[] 10
Connect spade terminals of low voltage wire to
spade terminals of transformer.
[] 11
Tumonalectridtyandtastoparationbyobasrvinglf
water is flowingto drain while fumace is running and humidistat
dial Is set to "toet"position.
AIR CONDmONING - IMPORTANT:
If your furnace has air conditioning (cooling),dose the damper
completely duringsummer months and tum the humidistat t o the
MinimumHumiditysetting.BE SURE TO OPEN DAMPER DUR-
ING HEATING SEASON AND RESETTHE HUMIDISTAT.
WATER FLOW RATE:
At standardwater line preseureof 50-60 PSI (poundsper square
inch), water willflow through humidifierat approximately four (4)
gallonsper hour.About 0.7 gallonspar hour of the four will be
evaporated,leaving3.3 gallons to be drainedaway.Since the fur-
nsoe only runsan estimated30-40% of the beating season, and
the_umldifter is wired to operate only with the fumase blower,
and only when humidityIs required,the actual amount of water
drainedper day is much less than wouldbe expected.