Motor Specifications And Electrical Requirements; Connecting To Power Source Outlet; Check Motor Rotation - Sears Craftsman 113.21371 Owner's Manual

15-1/2 inch drill press
Table of Contents

Advertisement

motor
specifications
and
electrical
requirements
MOTOR
SPECRFICATIONS
This
drill
press is designed
to use a 1725
RPM motor
only.
Do not use any motor
that
runs faster than
1725
RPM.
It
is wired
for
operation
on
1!0-120
volts,
60
Hz.,
alternating
current.
IT
MUST
NOT
BE CONVERTED
TO
OPERATE
ON
230
VOLTS,
EVEN
THOUGH
THE
RECOMMENDED
MOTORS
ARE
DUAL
VOLTAGE.
THESE CRAFTSMAN
MOTORS HAVE BEEN
FOUND
TO BE ACCEPTABLE
FOR USE ON
THiS TOOL.
HP
RPM
VOLTS
CATALOG
NO.
1/3
1725
110-120
1250
1/2
1725
110-120
!254
1/2
1725
!10-120
1255
1/2
1725
110-120
1278
1/2
1725
110q20
1279
CAUTBON:
Do not use blower
or washing
machine
motors
or any motor
with an automatic
reset overload
protector
as
their use may be hazardous.
CONNECTING
TO POWER SOURCE OUTLET
This machine must be grounded while in use to protect the
operator from electric shock.
Plug power cord into a 110-120V properly grounded type
outlet
protected
by a 15-amp. time delay or Circuit-Saver
fuse or circuit breaker.
iF YOU
ARE NOT SURE
THAT
YOUR
OUTLET
IS
PROPERLY
GROUNDED,
HAVE
IT CHECKED
BY A
QUALI FlED ELECTRICIAN.
WARNING:
DO NOT
PERMIT
FINGERS
TO TOUCH
THE TERMINALS
OF PLUGS WHEN
INSTALLING
OR
REMOVING
THE PLUG TO OR FROM THE OUTLET.
WARNING:
iF
NOT
PROPERLY
GROUNDED
THIS
POWER TOOL CAN INCUR THE POTENTIAL
HAZARD
OF
ELECTRICAL
SHOCK,
PARTICULARLY
WHEN
USED
IN
DAMP
LOCATIONS,
IN
PROXIMITY
TO
PLUMBING.
iF
AN
ELECTRICAL
SHOCK
OCCURS
THERE
iS THE
POTENTIAL
OF
A SECONDARY
HAZARD
SUCH AS YOUR HANDS CONTACTING
THE
CUTTING
TOOL.
If power cord is worn or cut, or damaged in any way, have
it replaced immediately.
PROPERLY
GROUNDED
OUTLET
\
3-PRONG
PLUG
U
GROUNDING
PRONG
If your
unit
is for use on less than t50
volts,
it has a plug
that looks
like above.
This
power
tool
is equipped
with
a 3-conductor
cord
and
grounding
type plug which
has a grounding
prong,
approved
by Underwriters'
Laboratories
and the Canadian
Standards
Association.
The ground
conductor
has a green jacket
and is
attached
to the tool
housing
at one end and to the ground
prong
in the attachment
plug at the other
end.
This
plug
requires
a mating
3-conductor
grounded
type
outlet
as shown.
if the outlet
you are planning
to use for this power
toot is
of the
two
prong
type
DO NOT
REMOVE
OR
ALTER
THE
GROUNDING
PRONG
IN ANY
MANNER.
Use an
adapter
as shown
and always
connect
the grounding
lug to
known
ground.
It
is recommended
that
you
have
a qualified
electrician
replace
the
TWO
prong
outlet
with
a properly
grounded
THREE
prong outlet.
An adapter
as shown
below
is available
for connecting
plugs
to 2°prong
receptacles.
The green grounding
lug extending
from
the adapter
must
be connected
to a permanent
ground
such as to a properly
grounded
outlet
box.
GROUNDING
LUG
ADAPTER
t I__._-_
MAKE SURE THIS IS
3-PRONG
CONNECTED
TO A
RECEPTACLE
NOTE:
The adapter
illustrated
is for use only if you already
have
a properly
grounded
2-prong
receptacle.
Adapter
is
not allowed
in Canada
by the Canadian
Electrical
Code.
The
use of any
extension
cord
will
cause
some
loss
of
power.
To
keep
this
to
a minimum
and
to
prevent
over-heating
and motor
burn-out,
use the table
below
to
determine
the minimum
wire
size (A.W.Go)
extension
cord.
Use
only
3 wire
extension
cords
which
'have
3 prong
grounding
type
plugs
and 3-pole
receptacles
which
accept
the tools plug.
Extension
Cord Length
Wire Size A.W.G.
Upto-lOOFt.
16
100-200
Ft.
14
200-400
Ft.
10
CHECK MOTOR ROTATION
WARNING:
FOR YOUR
OWN SAFETY,
MAKE
SURE
PLUG
IS NOT
CONNECTED
TO
POWER
SOURCE
OUTLET.
WHEN CHANGING
MOTOR ROTATION.
The motor
must rotate
CLOCKWISE
when viewed
from
the
shaft end to which
you will
mount
the pulley.
If
it
does
not,
change
the
direction
according
to
the
instructions
furnished
with
the motor.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Craftsman 113.213710

Table of Contents